Accuracy of Modern and Traditional Intraocular Lens Power Calculation Formulas in Pediatric Cataract Surgery
Clinical Ophthalmology · 2024-06 · Volume 18 · 1761-1769
DOI: 10.2147/opth.s468294 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Ophthalmology, 2024-06. Verfasst von Hany Ahmed Helaly und 3 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Purpose
To compare the accuracy of modern intraocular lens (IOL) power calculation formulas with that of older formulas, such as SRK/T and Hoffer Q, in pediatric cataract surgery.
Methods
This retrospective study included 100 eyes of 100 children who underwent routine cataract surgery with primary IOL implantation in a bag. This study used four IOLMaster 700 integrated formulas: SRK/T, Hoffer Q, Haigis, and Barrett Universal II (BUII). In addition, the following formulas were used: EVO 2.0, Hill RBF 3.0, Hoffer QST, Kane, and PEARL DGS, which are available online.
Results
There was a statistically significant difference between SRK/T and most other formulas, except for Hoffer Q, Hoffer QST, and BUII (p 0.05); Hoffer Q and SRK/T showed slightly better MedAE in this age group (5-10 years).
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt.
ORCID-Profile: Hany Ahmed Helaly
Zitieren
APA
Helaly, H. A., Said, M. H., Elnaggar, O. R., & Elkhawaga, M. H. (2024). Accuracy of Modern and Traditional Intraocular Lens Power Calculation Formulas in Pediatric Cataract Surgery. Clinical Ophthalmology, Volume 18, 1761-1769. https://doi.org/10.2147/opth.s468294
Vancouver
Helaly HA, Said MH, Elnaggar OR, Elkhawaga MH. Accuracy of Modern and Traditional Intraocular Lens Power Calculation Formulas in Pediatric Cataract Surgery. Clinical Ophthalmology. 2024;Volume 18:1761-1769. doi:10.2147/opth.s468294
BibTeX
@article{Helaly2024,
author = {Helaly, Hany Ahmed and Said, Mohamed Hassan and Elnaggar, Osama Ramadan and Elkhawaga, Mohamed Hassan},
title = {Accuracy of Modern and Traditional Intraocular Lens Power Calculation Formulas in Pediatric Cataract Surgery},
journal = {Clinical Ophthalmology},
year = {2024},
volume = {Volume 18},
pages = {1761--1769},
doi = {10.2147/opth.s468294}
}
EUVIMED