Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance
Physical and Engineering Sciences in Medicine · 2026
DOI: 10.1007/s13246-026-01750-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2026. Verfasst von Panxia Wu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Jiangxi Cancer Hospital (The Second Affiliated Hospital of Nanchang Medical College), Nanchang, 330029, Jiangxi, Ch…. Hauptthemen laut MEDLINE: Monte Carlo Method, Quality Assurance, Health Care, Radiotherapy, Intensity-Modulated, Computer Graphics. Die Arbeit nennt 49 Literaturangaben. Gefördert von: Jiangxi Cancer Hospital & Institute.
Abstract (Originalsprache)
The complex dose delivery mechanisms of TomoTherapy (TOMO) demand rigorous patient-specific quality assurance (PSQA). This study systematically evaluates the relationship between ArcCHECK measurements and GPU-accelerated Monte Carlo (GPU-MC) calculations for nasopharyngeal carcinoma (NPC) TOMO plans across multiple gamma criteria, aiming to delineate their respective strengths and inform an optimized verification strategy. A retrospective analysis was conducted on 317 TOMO plans for NPC, each optimized using the Accuray Precision Treatment Planning System. Patient-specific dose verification was performed using ArcCHECK measurements and independent MC calculations implemented through PlanQA. Gamma passing rates (GPRs) were evaluated under nine different conditions, including both same-criterion and cross-criterion comparisons. To assess differences, agreement, and correlations between methods, statistical analyses were conducted using the Wilcoxon signed-rank test, Bland-Altman analysis, and Spearman correlation. Under identical Gamma criteria, there was no statistically significant difference in GPR between ArcCHECK and MC. However, cross-criterion comparisons revealed marked discrepancies, highlighting the criterion-dependent nature of GPR outcomes. Lenient standards typically exhibit good consistency and relatively minor deviations. Furthermore, the correlations among all combinations of these standards can be considered negligible. The comparable performance of GPU-MC and ArcCHECK under conventional criteria (3%/3 mm, 3%/2 mm) validates ArcCHECK's established role in verifying delivery fidelity. Crucially, under the stringent 2%/2 mm criterion where ArcCHECK passing rates decline, MC provides critical diagnostic power to differentiate between discrepancies originating from the dose calculation algorithm and those arising from the physical delivery process. For TOMO PSQA, GPU-MC and ArcCHECK are complementary. An integrated approach leveraging both methods is therefore recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Jiangxi Cancer Hospital (The Second Affiliated Hospital of Nanchang Medical College), Nanchang, 330029, Jiangxi, China.
- School of Medical and Information Engineering, Gannan Medical University, Ganzhou, 341000, China.
- Jiangxi Clinical Research Center for Cancer, Nanchang, 330029, Jiangxi, China.
- Department of Radiation Oncology, Jiangxi Cancer Hospital (The Second Affiliated Hospital of Nanchang Medical College), Nanchang, 330029, Jiangxi, China. dsg8334922@163.com.
- School of Medical and Information Engineering, Gannan Medical University, Ganzhou, 341000, China. dsg8334922@163.com.
- Jiangxi Clinical Research Center for Cancer, Nanchang, 330029, Jiangxi, China. dsg8334922@163.com.
Förderung
- Jiangxi Cancer Hospital & Institute
Zitieren
APA
Wu, P., Zheng, W., Xu, L., Yuan, X., Gong, C., Luo, C., Jian, J., Ding, S., & Zhang, Y. (2026). Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-026-01750-2
Vancouver
Wu P, Zheng W, Xu L, Yuan X, Gong C, Luo C, et al. Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance. Physical and Engineering Sciences in Medicine. 2026. doi:10.1007/s13246-026-01750-2
BibTeX
@article{Wu2026,
author = {Wu, Panxia and Zheng, Wenheng and Xu, Longfei and Yuan, XingXing and Gong, Changfei and Luo, Changwei and Jian, Junming and Ding, Shenggou and Zhang, Yun},
title = {Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance},
journal = {Physical and Engineering Sciences in Medicine},
year = {2026},
doi = {10.1007/s13246-026-01750-2}
}
EUVIMED