EUVIMEDEUVIMED entdecken
Crossref

Addressing challenges in diagnostic X-ray dosimetry: uncertainties and corrections for Al2O3:C-based optically stimulated luminescent dosimeters

Jeannie Hsiu Ding Wong, Wan Hazlinda Ismail

Physical and Engineering Sciences in Medicine · 2024

DOI: 10.1007/s13246-024-01407-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Jeannie Hsiu Ding Wong und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. jeannie_wong80@um.edu.my. Hauptthemen laut MEDLINE: Aluminum Oxide, Optically Stimulated Luminescence Dosimetry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of Al2O3:C-based optically stimulated luminescent dosimeters (OSLDs) in diagnostic X-ray is a challenge because of their energy dependence (ED) and variability of element sensitivity factors (ESFs). This study aims to develop a method to determine ED and ESFs of Landauer nanoDot™ OSLDs for clinical X-ray and investigate the uncertainties associated with ESF and ED correction factors. An area of 2 × 2 cm2 at the central axis of the X-ray field was used to establish the ESFs. A total of 80 OSLDs were categorized into "controlled" (n = 40) and "less-controlled" groups (n = 40). The ESFs of the OSLDs were determined using an 80 kVp X-ray beam quality in free-air geometry. The OSLDs were cross-calibrated with an ion chamber to establish the average calibration coefficient and ESFs. The OSLDs were then irradiated at tube potentials ranging from 50 to 150 kVp to determine their ED. The uniformity of the X-ray field was ± 1.5% at 100 cm source-to-surface distance. The batch homogeneities of user-defined ESFs were 2.4% and 8.7% for controlled and less-controlled OSLDs, respectively. The ED of OSLDs ranged from 1.125 to 0.812 as tube potential increased from 50 kVp to 150 kVp. The total uncertainty of OSLDs, without ED correction, could be as high as 16%. After applying ESF and ED correction, the total uncertainties were reduced to 6.3% in controlled OLSDs and 11.6% in less-controlled ones. OSLDs corrected with user-defined ESF and ED can reduce the uncertainty of dose measurements in diagnostic X-rays, particularly in managing less-controlled OSLDs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aluminum OxideOptically Stimulated Luminescence DosimetryUncertaintyX-RaysCalibrationCarbonRadiometryRadiation DosimetersLuminescence

Stichwörter der Autor:innen

Element correction factorsEnergy dependenceIn vivo dosimetryKilovoltage X-raysOSLDs

Substanzen

Aluminum OxideCarbon

Autor:innen und Institutionen

  • Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. jeannie_wong80@um.edu.my.
  • Medical Physics Laboratory, Radiation Safety and Health Division, Malaysian Nuclear Agency, 43000, Bangi, Kajang, Selangor, Malaysia. jeannie_wong80@um.edu.my.
  • Universiti Malaya Research Imaging Centre (UMRIC), Universiti Malaya, 50603, Kuala Lumpur, Malaysia. jeannie_wong80@um.edu.my.
  • Medical Physics Laboratory, Radiation Safety and Health Division, Malaysian Nuclear Agency, 43000, Bangi, Kajang, Selangor, Malaysia.

Zitieren

APA

Wong, J. H. D., & Ismail, W. H. (2024). Addressing challenges in diagnostic X-ray dosimetry: uncertainties and corrections for Al2O3:C-based optically stimulated luminescent dosimeters. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01407-y

Vancouver

Wong JHD, Ismail WH. Addressing challenges in diagnostic X-ray dosimetry: uncertainties and corrections for Al2O3:C-based optically stimulated luminescent dosimeters. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01407-y

BibTeX
@article{Wong2024,
  author = {Wong, Jeannie Hsiu Ding and Ismail, Wan Hazlinda},
  title = {Addressing challenges in diagnostic X-ray dosimetry: uncertainties and corrections for Al2O3:C-based optically stimulated luminescent dosimeters},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2024},
  doi = {10.1007/s13246-024-01407-y}
}
Kostenlos starten →