Fluorescence X-ray field for radiation dosemeters calibration

Tomoya Tsuji, Hiroshi Yoshitomi, Fuminobu Sato, Yoshihiko Tanimura

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Tomoya Tsuji und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-…. Hauptthemen laut MEDLINE: Radiation Dosimeters, Radiation Monitoring, Radiation Protection, Radiometry. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An irradiation environment for dosemeters calibration in the fluorescence X-ray field was set up at the Facility of Radiation Standards of the Japan Atomic Energy Agency by re-establishing the fluorescence X-ray calibration field that was established in 1989. The reference air kerma rates were determined using reference ionization chambers calibrated using X-ray narrow-spectrum series calibration field of the national metrology standard in Japan. Since no X-ray calibration field using fluorescence X-rays is available in Japan, the measurements were corrected by factors that accounts for differences in the fluorescence X-ray calibration field energy and the X-ray narrow-spectrum series calibration field energy. The conversion coefficients and correction factors for air densities for the fluorescence X-ray calibration field, including those unavailable in the ISO 4037 standard series, were derived from the measured X-ray fluence rate spectra.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosimetersRadiation MonitoringRadiation ProtectionRadiometryCalibrationX-RaysJapanRadiation DosageFluorescenceHumans

Autor:innen und Institutionen

  • Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, Japan.
  • Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan.

Zitieren

APA

Tsuji, T., Yoshitomi, H., Sato, F., & Tanimura, Y. (2025). Fluorescence X-ray field for radiation dosemeters calibration. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf060

Vancouver

Tsuji T, Yoshitomi H, Sato F, Tanimura Y. Fluorescence X-ray field for radiation dosemeters calibration. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf060

BibTeX
@article{Tsuji2025,
  author = {Tsuji, Tomoya and Yoshitomi, Hiroshi and Sato, Fuminobu and Tanimura, Yoshihiko},
  title = {Fluorescence X-ray field for radiation dosemeters calibration},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf060}
}
Kostenlos starten →