A clinically feasible model for size-specific estimation of eye lens dose in head CT
Radiological Physics and Technology · 2026
DOI: 10.1007/s12194-026-01022-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiological Physics and Technology, 2026. Verfasst von S Sookpeng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand. Hauptthemen laut MEDLINE: Lens, Crystalline, Tomography, X-Ray Computed, Radiation Dosage, Head. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
This study aimed to develop and validate a simplified, size-specific model for estimating eye lens dose during head CT imaging, addressing the limitations of generalized size-based methods for anatomically peripheral structures. An equation using effective diameter (DEff) was derived from Monte Carlo simulations covering head sizes of 9.9-19.5 cm and CTDIvol values of 7-160 mGy. DEff was selected for its direct measurability from axial CT images. Validation was performed using OSL dosimeters in phantoms across three scanner platforms, comparing model estimates with measurements and SSDE values calculated by AAPM Reports 204 and 293.The equation was derived for 120 kV head CT protocols. The final exponential model demonstrated excellent agreement with reference values R2 = 0.996, MAE = 0.94 mGy, RMSE = 1.27 mGy). SSDE-based estimates showed larger discrepancies, particularly in smaller head sizes. The model's correction factor exhibited a more gradual decline with increasing DEff, accurately reflecting the dose-size relationship of anteriorly located structures. This study presents a practical size-specific approach for eye lens dose estimation in head CT, providing better alignment with reference values than generalized SSDE methods. The model can be readily implemented in clinical workflows, particularly benefiting emergency scenarios requiring rapid individualized dose estimation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand.
- Thailand Institute of Nuclear Technology, Ongkarak District, Nakhon Nayok, Thailand.
- Department of Clinical Physics and Bioengineering, Institute of Neurosciences and Psychology, University of Glasgow, Glasgow, G12 8QQ, UK.
- Department of Radiology, Buddhachinaraj Phitsanulok Hospital, Phitsanulok, Thailand.
- Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand. bouripatk@nu.ac.th.
Zitieren
APA
Sookpeng, S., Rattanarungruangchai, N., López-Gonzalez, M. R., Chanlaor, S., & Kadman, B. (2026). A clinically feasible model for size-specific estimation of eye lens dose in head CT. Radiological Physics and Technology. https://doi.org/10.1007/s12194-026-01022-4
Vancouver
Sookpeng S, Rattanarungruangchai N, López-Gonzalez MR, Chanlaor S, Kadman B. A clinically feasible model for size-specific estimation of eye lens dose in head CT. Radiological Physics and Technology. 2026. doi:10.1007/s12194-026-01022-4
BibTeX
@article{Sookpeng2026,
author = {Sookpeng, S and Rattanarungruangchai, N and López-Gonzalez, M R and Chanlaor, S and Kadman, Boriphat},
title = {A clinically feasible model for size-specific estimation of eye lens dose in head CT},
journal = {Radiological Physics and Technology},
year = {2026},
doi = {10.1007/s12194-026-01022-4}
}