Single-point macromolecular proton fraction mapping using a 0.3 T permanent magnet MRI system: phantom and healthy volunteer study
Radiological Physics and Technology · 2024
DOI: 10.1007/s12194-024-00843-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Yasuhiro Fujiwara und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging Technology, Faculty of Life Sciences, Kumamoto University, 4-24-1, Kuhonji, Chuo-Ku, Kumamoto, 862-0976, Japan. yfuji@k…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Protons, Healthy Volunteers. Die Arbeit nennt 32 Literaturangaben. Gefördert von: JSPS KAKENHI.
Abstract (Originalsprache)
In a 0.3 T permanent-magnet magnetic resonance imaging (MRI) system, quantifying myelin content is challenging owing to long imaging times and low signal-to-noise ratio. macromolecular proton fraction (MPF) offers a quantitative assessment of myelin in the nervous system. We aimed to demonstrate the practical feasibility of MPF mapping in the brain using a 0.3 T MRI. Both 0.3 T and 3.0 T MRI systems were used. The MPF-mapping protocol used a standard 3D fast spoiled gradient-echo sequence based on the single-point reference method. Proton density, T1, and magnetization transfer-weighted images were obtained from a protein phantom at 0.3 T and 3.0 T to calculate MPF maps. MPF was measured in all phantom sections to assess its relationship to protein concentration. We acquired MPF maps for 16 and 8 healthy individuals at 0.3 T and 3.0 T, respectively, measuring MPF in nine brain tissues. Differences in MPF between 0.3 T and 3.0 T, and between 0.3 T and previously reported MPF at 0.5 T, were investigated. Pearson's correlation coefficient between protein concentration and MPF at 0.3 T and 3.0 T was 0.92 and 0.90, respectively. The 0.3 T MPF of brain tissue strongly correlated with 3.0 T MPF and literature values measured at 0.5 T. The absolute mean differences in MPF between 0.3 T and 0.5 T were 0.42% and 1.70% in white and gray matter, respectively. Single-point MPF mapping using 0.3 T permanent-magnet MRI can effectively assess myelin content in neural tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging Technology, Faculty of Life Sciences, Kumamoto University, 4-24-1, Kuhonji, Chuo-Ku, Kumamoto, 862-0976, Japan. yfuji@kumamoto-u.ac.jp.
- Department of Radiology, Hospital of the University of Occupational and Environmental Health, 1-1, Iseigaoka, Yahatanishi-Ku, Kitakyushu, 807-8556, Japan.
- Department of Neurology, National Hospital Organization Omuta National Hospital, 1044-1, Tachibana, Omuta, 837-0911, Japan.
- Department of Radiology, National Hospital Organization Kumamoto Saishun Medical Center, 2659 Suya, Koshi, Kumamoto, 861-1196, Japan.
- Department of Radiology, National Hospital Organization Omuta National Hospital, 1044-1, Tachibana, Omuta, 837-0911, Japan.
- Department of Diagnostic Imaging Technology, Faculty of Life Sciences, Kumamoto University, 4-24-1, Kuhonji, Chuo-Ku, Kumamoto, 862-0976, Japan.
Förderung
- JSPS KAKENHI
Zitieren
APA
Fujiwara, Y., Eitoku, S., Sakae, N., Izumi, T., Kumazoe, H., & Kitajima, M. (2024). Single-point macromolecular proton fraction mapping using a 0.3 T permanent magnet MRI system: phantom and healthy volunteer study. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00843-5
Vancouver
Fujiwara Y, Eitoku S, Sakae N, Izumi T, Kumazoe H, Kitajima M. Single-point macromolecular proton fraction mapping using a 0.3 T permanent magnet MRI system: phantom and healthy volunteer study. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00843-5
BibTeX
@article{Fujiwara2024,
author = {Fujiwara, Yasuhiro and Eitoku, Shoma and Sakae, Nobutaka and Izumi, Takahisa and Kumazoe, Hiroyuki and Kitajima, Mika},
title = {Single-point macromolecular proton fraction mapping using a 0.3 T permanent magnet MRI system: phantom and healthy volunteer study},
journal = {Radiological Physics and Technology},
year = {2024},
doi = {10.1007/s12194-024-00843-5}
}
EUVIMED