Radiation safety in catheter ablation: clinical value of real-time operator dosimetry
Heart and Vessels · 2025
DOI: 10.1007/s00380-025-02567-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart and Vessels, 2025. Verfasst von Machiko Miyoshi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, …. Hauptthemen laut MEDLINE: Catheter Ablation, Radiation Exposure, Occupational Exposure, Radiography, Interventional. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Fukui.
Abstract (Originalsprache)
Advances in interventional cardiology have increased procedural complexity, raising concerns about radiation exposure—especially for women operators of reproductive age, who are subject to stricter dose limits. Standard dosimeters provide only delayed cumulative data, limiting timely risk assessment. Real-time personal dosimetry offers immediate feedback, but its clinical utility during catheter ablation (CA) remains underexplored. We retrospectively analyzed 82 CA procedures performed between January and May 2024. First operators wore real-time dosimeters positioned at the waist under lead aprons. Radiation exposure and procedural characteristics were recorded and analyzed. The median operator radiation dose per procedure was 2 [1, 3] µSv, while the median patient dose was 0.163 [0.082, 0.324] Gy. A procedure-related cardiac tamponade requiring pericardiocentesis resulted in the highest operator dose (50 µSv). Higher patient BMI (≥ 25 kg/m 2 ) and longer fluoroscopy time were independently associated with increased operator exposure (OR: 1.238, P = 0.008; OR: 1.056, P = 0.022), though no linear correlation was observed between BMI and operator dose (r = 0.029, P = 0.797). Radiation exposure to operators during CA is generally low but may increase significantly in the event of complications or with higher-risk patient characteristics. Real-time dosimetry provides valuable immediate feedback and may be especially important for radiation-sensitive operators, supporting safer practice in the evolving field of interventional electrophysiology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.
- Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan. kanaeh@u-fukui.ac.jp.
- Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
Förderung
- University of Fukui
Zitieren
APA
Miyoshi, M., Hasegawa, K., Maruyama, R., Tateishi, T., Nomura, R., Tsuji, T., Mukai, M., Tsujikawa, T., Uzui, H., & Tada, H. (2025). Radiation safety in catheter ablation: clinical value of real-time operator dosimetry. Heart and Vessels. https://doi.org/10.1007/s00380-025-02567-x
Vancouver
Miyoshi M, Hasegawa K, Maruyama R, Tateishi T, Nomura R, Tsuji T, et al. Radiation safety in catheter ablation: clinical value of real-time operator dosimetry. Heart and Vessels. 2025. doi:10.1007/s00380-025-02567-x
BibTeX
@article{Miyoshi2025,
author = {Miyoshi, Machiko and Hasegawa, Kanae and Maruyama, Rikiya and Tateishi, Toshiki and Nomura, Ryohei and Tsuji, Toshihiko and Mukai, Moe and Tsujikawa, Tetsuya and Uzui, Hiroyasu and Tada, Hiroshi},
title = {Radiation safety in catheter ablation: clinical value of real-time operator dosimetry},
journal = {Heart and Vessels},
year = {2025},
doi = {10.1007/s00380-025-02567-x}
}
EUVIMED