Improving Hounsfield Unit accuracy in dental CBCT through the integration of 2D anti-scatter grid
Oral Radiology · 2025
DOI: 10.1007/s11282-025-00824-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Oral Radiology, 2025. Verfasst von Ryan Sabounchi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Colorado Denver, 12705 East Montview Boulevard, Suite 100, Aurora, CO, 80045, USA. ryan.sabounchi@ucdenve…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Radiography, Dental. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCR NIH HHS, NHLBI NIH HHS, NIH HHS.
Abstract (Originalsprache)
OBJECTIVE: Lack of Hounsfield Unit (HU) accuracy leads to misrepresentation of tissue densities and causes image artifacts in dental cone beam computed tomography (CBCT) images. This work investigates the improvement in HU accuracy in dental CBCT by suppressing scatter with a novel two-dimensional anti-scatter grid (2D ASG) approach. METHODS: A 2D ASG prototype was developed and integrated into an experimental CBCT system, emulating dental CBCT geometry. CBCT scans were acquired using a multidetector CT (MDCT), a clinical dental CBCT, and the proposed 2D ASG-based experimental CBCT system. Subsequently, HU accuracy, nonuniformity, and contrast-to-noise ratio (CNR) were evaluated in image quality phantoms benchmarked against MDCT images. The effect of scatter suppression on the implant-induced HU degradation was also studied. RESULTS: 2D ASG reduced scatter content up to a factor of 6.6 in CBCT scans and HU nonuniformity in soft tissue-like regions was reduced from 23 to 4 HU. HU errors in high-density structures were within 65 HU of values measured in the gold standard MDCT images. Robust scatter suppression also reduced streak artifacts caused by implants. CNR increased up to 47% in images acquired with the 2D ASG. CONCLUSION: HU accuracy in dental CBCT may reach the accuracy of MDCT with the proposed 2D ASG. Moreover, artifacts are reduced, and contrast visualization can be improved. Hence, this approach may enable a more accurate assessment of tissue densities in CBCT images, and improved image quality may positively impact the diagnostic capabilities of dental CBCT systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, University of Colorado Denver, 12705 East Montview Boulevard, Suite 100, Aurora, CO, 80045, USA. ryan.sabounchi@ucdenver.edu.
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA. ryan.sabounchi@ucdenver.edu.
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA.
- Department of Radiology, Houston Methodist Hospital, 6565 Fannin St, Houston, Texas, 77030, USA.
- School of Dental Medicine, University of Colorado Anschutz, 13065 East 17 Avenue, Aurora, CO, 80045, USA.
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA. cem.altunbas@cuanschutz.edu.
ORCID-Profile: Ryan Sabounchi
Förderung
- NIDCR NIH HHS
- NHLBI NIH HHS
- NIH HHS
- NCI NIH HHS
- National Institutes of Health
Zitieren
APA
Sabounchi, R., Pyakurel, U., Bayat, F., Eldib, M., Ozus, B., Crockett, B., & Altunbas, C. (2025). Improving Hounsfield Unit accuracy in dental CBCT through the integration of 2D anti-scatter grid. Oral Radiology. https://doi.org/10.1007/s11282-025-00824-3
Vancouver
Sabounchi R, Pyakurel U, Bayat F, Eldib M, Ozus B, Crockett B, et al. Improving Hounsfield Unit accuracy in dental CBCT through the integration of 2D anti-scatter grid. Oral Radiology. 2025. doi:10.1007/s11282-025-00824-3
BibTeX
@article{Sabounchi2025,
author = {Sabounchi, Ryan and Pyakurel, Uttam and Bayat, Farhang and Eldib, Mohamed and Ozus, Bahadir and Crockett, Benjamin and Altunbas, Cem},
title = {Improving Hounsfield Unit accuracy in dental CBCT through the integration of 2D anti-scatter grid},
journal = {Oral Radiology},
year = {2025},
doi = {10.1007/s11282-025-00824-3}
}
EUVIMED