EUVIMEDEUVIMED entdecken
Open Access

A simulation study to evaluate the effect of 2D antiscatter grid primary transmission on flat panel detector based CBCT image quality

Mohamed Elsayed Eldib iD, Farhang Bayat, Moyed Miften, Cem Altunbas

Biomedical Physics & Engineering Express · 2023

DOI: 10.1088/2057-1976/acfb8a ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2023. Verfasst von Mohamed Elsayed Eldib und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706, Aurora, CO 80045, United…. Hauptthemen laut MEDLINE: Spiral Cone-Beam Computed Tomography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIH/NCI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Abstact Purpose . Two-dimensional antiscatter grids’ (2D-ASGs) septal shadows and their impact on primary transmission play a critical role in cone-beam computed tomography (CBCT) image noise and artifact characteristics. Therefore, a numerical simulation platform was developed to evaluate the effect of 2D-ASG’s primary transmission on image quality, as a function of grid geometry and CBCT system properties.

Methods

To study the effect of 2D-ASG’s septal shadows on primary transmission and CBCT image quality, two new methods were introduced; one to simulate projection signal gradients in septal shadows, and the other to simulate septal shadow variations due to gantry flex. Signal gradients in septal shadows were simulated by generating a system point spread function that was directly extracted from projection images of 2D-ASG prototypes in experiments. Variations in septal shadows due to gantry flex were simulated by generating oversampled shadow profiles extracted from experiments. Subsequently, the effect of 2D-ASG’s septal shadows on primary transmission and image quality was evaluated.

Results

For an apparent septal thickness of 0.15 mm, the primary transmission of 2D-ASG varied between 72%–90% for grid pitches 1–3 mm. In low-contrast phantoms, the effect of 2D-ASG’s radiopaque footprint on information loss was subtle. At high spatial frequencies, information loss manifested itself as undersampling artifacts, however, its impact on image quality is subtle when compared to quantum noise. Effects of additive electronic noise and gantry flex induced ring artifacts on image quality varied as a function of grid pitch and septal thickness. Such artifacts were substantially less in lower resolution images.

Conclusion

The proposed simulation platform allowed successful evaluation of CBCT image quality variations as a function of 2D-ASG primary transmission properties and CBCT system characteristics. This platform can be potentially used for optimizing 2D-ASG design properties based on the imaging task and properties of the CBCT system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spiral Cone-Beam Computed TomographyScattering, RadiationPhantoms, ImagingCone-Beam Computed TomographyArtifacts

Stichwörter der Autor:innen

2D antiscatter gridCBCTimage quality

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706, Aurora, CO 80045, United States of America.

ORCID-Profile: Mohamed Elsayed Eldib

Förderung

  • NCI NIH HHS
  • NIH/NCI

Zitieren

APA

Eldib, M. E., Bayat, F., Miften, M., & Altunbas, C. (2023). A simulation study to evaluate the effect of 2D antiscatter grid primary transmission on flat panel detector based CBCT image quality. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/acfb8a

Vancouver

Eldib ME, Bayat F, Miften M, Altunbas C. A simulation study to evaluate the effect of 2D antiscatter grid primary transmission on flat panel detector based CBCT image quality. Biomedical Physics & Engineering Express. 2023. doi:10.1088/2057-1976/acfb8a

BibTeX
@article{Eldib2023,
  author = {Eldib, Mohamed Elsayed and Bayat, Farhang and Miften, Moyed and Altunbas, Cem},
  title = {A simulation study to evaluate the effect of 2D antiscatter grid primary transmission on flat panel detector based CBCT image quality},
  journal = {Biomedical Physics & Engineering Express},
  year = {2023},
  doi = {10.1088/2057-1976/acfb8a}
}
Kostenlos starten →