EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and characterisation of PEI/HA filaments for fused filament fabrication (FFF) in biomedical applications

Conor McCrickard, Adrian Boyd, Edward Archer, Faisal Manzoor, Ben Groogan, Aoife McFerran, Jawad Ullah

Journal of Materials Science · 28.10.2026

DOI: 10.1007/s10853-026-13974-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Materials Science, online erschienen am 28.10.2026. Verfasst von Conor McCrickard und 6 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Polyetherimide (PEI) has recently been used in additive manufacturing as it possesses excellent mechanical and thermal properties. These properties have led to its applications across industries including aerospace, automotive, and medical industries. The use of high-performance polymers (HPP) possess attractive properties in relation to medical devices; however, concerns remain with respect to bioactivity. Addition of bioactive fillers to mitigate against this has been considered, such as hydroxyapatite (HA), the main mineral component of human bone. This study considers the preparation and characterisation of PEI-based filaments containing 10, 20, and 30 wt.% of HA and then subsequently printed using fused filament fabrication (FFF). Mechanical, thermal, and morphological analysis was performed. Bioactivity was investigated via immersion in simulated body fluid (SBF) and cell studies conducted using mesenchymal stem cells (MSC). Results revealed a significant decrease in ultimate tensile strength (UTS) compared to neat PEI. Young’s modulus peaked at 1683 MPa for PEIHA-20%. Scanning electron microscopy (SEM) and SEM-energy dispersion X-rays (EDX) confirmed apatite-like precipitates through the detection of calcium and phosphorus elements on the top surface of the samples after 7 days of immersion. Cell metabolic activity increased from day 1 to 3 and plateaued at day 7. The results demonstrate that the addition of hydroxyapatite to PEI is a promising material candidate for further biomedical evaluation.

Zitieren

APA

McCrickard, C., Boyd, A., Archer, E., Manzoor, F., Groogan, B., McFerran, A., & Ullah, J. (2026). Design and characterisation of PEI/HA filaments for fused filament fabrication (FFF) in biomedical applications. Journal of Materials Science. https://doi.org/10.1007/s10853-026-13974-4

Vancouver

McCrickard C, Boyd A, Archer E, Manzoor F, Groogan B, McFerran A, et al. Design and characterisation of PEI/HA filaments for fused filament fabrication (FFF) in biomedical applications. Journal of Materials Science. 2026. doi:10.1007/s10853-026-13974-4

BibTeX
@article{McCrickard2026,
  author = {McCrickard, Conor and Boyd, Adrian and Archer, Edward and Manzoor, Faisal and Groogan, Ben and McFerran, Aoife and Ullah, Jawad},
  title = {Design and characterisation of PEI/HA filaments for fused filament fabrication (FFF) in biomedical applications},
  journal = {Journal of Materials Science},
  year = {2026},
  doi = {10.1007/s10853-026-13974-4}
}
Kostenlos starten →