Beobachtungsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 08.08.2026. Verfasst von Misaki Naka und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Mitsubishi Kyoto Hospital, 1 Katsuragoshocho, Nishikyo-Ku, Kyoto, 615-8087, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Electrocardiography. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Catheter ablation for atrial fibrillation (AF) carries a known risk of tachyarrhythmia recurrence, but the recurrence is still difficult to predict before the procedure. This study assessed the value of noninvasive f-wave vector magnitude (FVM) during AF in predicting recurrence following ablation. METHODS: This observational study included 604 consecutive patients who underwent initial AF ablation between January 2017 and December 2022 at Mitsubishi Kyoto Hospital, and whose baseline 12-lead electrocardiograms during AF were available. The maximal f-wave amplitude (FWA) over a 10-s period was measured manually using computerized calipers, and FVM was defined as the magnitude of atrial depolarization in three-dimensional space, calculated using the visually transformed Kors' quasi-orthogonal method. The outcome measure was the recurrence of atrial tachyarrhythmias after a 90-day post-procedural blanking period. RESULTS: The median follow-up was 5.4 (3.9-7.1) years. In multivariable analysis, low FVM (< 0.18 mV) was an independent predictor of recurrence (hazard ratio [HR] = 1.56, 95% confidence interval [CI] = 1.16-2.15, p < 0.01) as well as left atrial dilatation (≥ 45 mm) (HR = 1.46, 95% CI = 1.08-1.98, p = 0.01). The 5-year recurrence-free rate after initial ablation was lowest in patients with both low FVM and left atrial dilatation (53.9%), and highest in those with neither (78.3%, p < 0.001). The risk stratification was only clear in patients with non-paroxysmal AF (49.4% vs. 79.9%, p < 0.001). In contrast, FWA below 0.10 mV in lead V1, defined as a fine f-wave, was not associated with recurrence following ablation. CONCLUSIONS: Noninvasive FVM measurement stratified the risk of recurrence after AF ablation in patients with non-paroxysmal AF, but did not show predictive value in those with paroxysmal AF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationElectrocardiographyHumansRecurrenceFemaleMalePredictive Value of TestsTreatment OutcomeMiddle AgedAged

Stichwörter der Autor:innen

Atrial fibrillationCatheter ablationElectrocardiogramF-wave vector magnitudeLeft atrial dilatation

Autor:innen und Institutionen

  • Department of Cardiology, Mitsubishi Kyoto Hospital, 1 Katsuragoshocho, Nishikyo-Ku, Kyoto, 615-8087, Japan.
  • Department of Cardiology, Mitsubishi Kyoto Hospital, 1 Katsuragoshocho, Nishikyo-Ku, Kyoto, 615-8087, Japan. kawaji@kuhp.kyoto-u.ac.jp.
  • Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan. kawaji@kuhp.kyoto-u.ac.jp.

Zitieren

APA

Naka, M., Kawaji, T., Bao, B., Kimura, T., Hojo, S., Matsuda, S., Kato, M., Yokomatsu, T., & Miki, S. (2026). F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 69(9), 2989-2997. https://doi.org/10.1007/s10840-026-02416-5

Vancouver

Naka M, Kawaji T, Bao B, Kimura T, Hojo S, Matsuda S, et al. F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology. 2026;69(9):2989-2997. doi:10.1007/s10840-026-02416-5

BibTeX
@article{Naka2026,
  author = {Naka, Misaki and Kawaji, Tetsuma and Bao, Bingyuan and Kimura, Tomoya and Hojo, Shun and Matsuda, Shintaro and Kato, Masashi and Yokomatsu, Takafumi and Miki, Shinji},
  title = {F-wave vector magnitude predicts recurrence after catheter ablation of atrial fibrillation},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  volume = {69},
  number = {9},
  pages = {2989--2997},
  doi = {10.1007/s10840-026-02416-5}
}
Kostenlos starten →