P‐wave alternans rebound following pulmonary vein isolation predicts atrial arrhythmia recurrence

Bruce D Nearing iD, Guilherme L Fialho iD, Jonathan W Waks iD, Timothy R Maher iD, John-Ross Clarke iD, Alyssa J Shepherd iD, Andre D'Avila iD, Richard L Verrier iD

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16291 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Bruce D Nearing und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Recurrence, Catheter Ablation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Numerous P‐wave indices have been explored as biomarkers to assess atrial fibrillation (AF) risk and the impact of therapy with variable success.

Objective

We investigated the utility of P‐wave alternans (PWA) to track the effects of pulmonary vein isolation (PVI) and to predict atrial arrhythmia recurrence.

Methods

This medical records study included patients who underwent PVI for AF ablation at our institution, along with 20 control subjects without AF or overt cardiovascular disease. PWA was assessed using novel artificial intelligence‐enabled modified moving average (AI‐MMA) algorithms. PWA was monitored from the 12‐lead ECG at ~1 h before and ~16 h after PVI ( n = 45) and at the 4‐ to 17‐week clinically indicated follow‐up visit ( n = 30). The arrhythmia follow‐up period was 955 ± 112 days.

Results

PVI acutely reduced PWA by 48%–63% ( p < .05) to control ranges in leads II, III, aVF, the leads with the greatest sensitivity in monitoring PWA. Pre‐ablation PWA was ~6 µV and decreased to ~3 µV following ablation. Patients who exhibited a rebound in PWA to pre‐ablation levels at 4‐ to 17‐week follow‐up ( p < .01) experienced recurrent atrial arrhythmias, whereas patients whose PWA remained reduced ( p = .85) did not, resulting in a significant difference ( p < .001) at follow‐up. The AUC for PWA's prediction of first recurrence of atrial arrhythmia was 0.81 ( p < .01) with 88% sensitivity and 82% specificity. Kaplan–Meier analysis estimated atrial arrhythmia‐free survival ( p < .01) with an adjusted hazard ratio of 3.4 (95% CI: 1.47–5.24, p < .02).

Conclusion

A rebound in PWA to pre‐ablation levels detected by AI‐MMA in the 12‐lead ECG at standard clinical follow‐up predicts atrial arrhythmia recurrence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary VeinsAtrial FibrillationRecurrenceCatheter AblationAction PotentialsPredictive Value of TestsHeart RateElectrocardiographyHumansMaleFemaleMiddle AgedAgedTime FactorsTreatment OutcomeRisk FactorsRetrospective StudiesCase-Control Studies

Stichwörter der Autor:innen

P‐wave alternansR‐wave alternansT‐wave alternansartificial intelligenceatrial fibrillationmodified moving averagepulmonary vein isolation

Autor:innen und Institutionen

  • Department of Neurology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
  • Federal University of Santa Catarina, Florianopolis, Brazil.
  • Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.

ORCID-Profile: Bruce D Nearing, Guilherme L Fialho, Jonathan W Waks, Timothy R Maher, John-Ross Clarke, Alyssa J Shepherd, Andre D'Avila, Richard L Verrier

Zitieren

APA

Nearing, B. D., Fialho, G. L., Waks, J. W., Maher, T. R., Clarke, J. R., Shepherd, A. J., D'Avila, A., & Verrier, R. L. (2024). P‐wave alternans rebound following pulmonary vein isolation predicts atrial arrhythmia recurrence. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16291

Vancouver

Nearing BD, Fialho GL, Waks JW, Maher TR, Clarke JR, Shepherd AJ, et al. P‐wave alternans rebound following pulmonary vein isolation predicts atrial arrhythmia recurrence. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16291

BibTeX
@article{Nearing2024,
  author = {Nearing, Bruce D and Fialho, Guilherme L and Waks, Jonathan W and Maher, Timothy R and Clarke, John-Ross and Shepherd, Alyssa J and D'Avila, Andre and Verrier, Richard L},
  title = {P‐wave alternans rebound following pulmonary vein isolation predicts atrial arrhythmia recurrence},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16291}
}
Kostenlos starten →