Multizentrische Studie in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Yuanyuan Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, State Key Laboratory of Organ Failure Research, Nanfang Hospital, Southern Medical University, Guangzhou, Chin…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Electrocardiography. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
Background
Predicting recurrence after radiofrequency catheter ablation (RFCA) in persistent atrial fibrillation (PeAF) remains challenging. This study evaluated the predictive value of F‐wave amplitude (FWA), F‐wave duration (FWD) in inferior ECG leads (II, III, aVF), and AF duration for post‐ablation recurrence.
Methods
In this dual‐center retrospective study, 763 persistent atrial fibrillation (PeAF) patients undergoing first RFCA (2017–2022) were analyzed. Pre‐procedural FWA and FWD were measured across 12‐lead ECGs using MATLAB. Clinical data and 12‐month follow‐up outcomes were collected. Independent predictors were identified via binary logistic regression, and a gradient boosting machine (GBM) model was developed. Model performance was assessed using ROC curves, calibration plots, and decision curve analysis (DCA), with internal (random split) and external (between‐center) validation.
Results
At 12 months, 198 patients (26%) experienced recurrence. Recurrence patients exhibited significantly lower inferior lead FWA (0.108 [0.076–0.157] vs. 0.126 [0.087–0.173] mV, p = 0.003), narrower FWD (54.96 [40.26–71.31] vs. 61.46 [42.7–76] ms, p = 0.038), and longer AF duration (13.8 [4–38] vs. 6.5 [3–21] months, p < 0.001). Multivariate analysis identified inferior lead FWA (OR = 0.788, 95%CI 0.662–0.937, p = 0.007) and AF duration (OR = 1.014, 95%CI 1.007–1.021, p < 0.001) as independent predictors. The model combining AF duration and FWA achieved an AUC of 0.692 (95%CI 0.648–0.737), improving to 0.746 (0.701–0.787) with FWD inclusion. Validation demonstrated stable discrimination (internal AUC = 0.722, 95%CI 0.680–0.762; external AUC = 0.703, 0.659–0.747).
Conclusion
Inferior lead FWA and AF duration are independent predictors of post‐RFCA recurrence in persistent AF. The combined model integrating these parameters with FWD shows robust discriminative ability and clinical utility, supporting personalized treatment strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, State Key Laboratory of Organ Failure Research, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Department of Cardiovascular Medicine, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Provincial People's Hospital, Nanjing, China.
ORCID-Profile: Yuanyuan Chen, Linlin Wang
Zitieren
APA
Chen, Y., Wang, L., Sun, L., Wen, J., Tan, N., Deng, H., Rehman, A., Wu, J., Bin, J., Liao, Y., Chen, H., Chen, M., & Wang, Y. (2025). Combined F‐wave and AF Duration Predict Post‐Ablation Recurrence in Persistent AF: Dual‐Center Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70064
Vancouver
Chen Y, Wang L, Sun L, Wen J, Tan N, Deng H, et al. Combined F‐wave and AF Duration Predict Post‐Ablation Recurrence in Persistent AF: Dual‐Center Study. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70064
BibTeX
@article{Chen2025,
author = {Chen, Yuanyuan and Wang, Linlin and Sun, Lan and Wen, Jialing and Tan, Na and Deng, Haozhe and Rehman, Arsh and Wu, Juefei and Bin, Jianping and Liao, Yulin and Chen, Hongwu and Chen, Minglong and Wang, Yuegang},
title = {Combined F‐wave and AF Duration Predict Post‐Ablation Recurrence in Persistent AF: Dual‐Center Study},
journal = {Pacing and Clinical Electrophysiology},
year = {2025},
doi = {10.1111/pace.70064}
}
EUVIMED