A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
Journal of Cardiothoracic Surgery · 2025
DOI: 10.1186/s13019-024-03335-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiothoracic Surgery, 2025. Verfasst von Li-Juan Yu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian C…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Nomograms, Catheter Ablation, Electrocardiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVE: The objective of this study is to assess the predictive utility of perioperative P-wave parameters in patients with paroxysmal atrial fibrillation (PAF) undergoing catheter ablation, and to develop a predictive model using these parameters. METHODS: A total of 213 patients with PAF undergoing catheter ablation were retrospectively analyzed. P-wave parameters were measured within 3 days preoperatively and on the day postoperatively to determine their predictive significance for postoperative PAF recurrence. RESULTS: Post-ablation, PAF did not recur in 168 patients, while 45 experienced recurrence. Significant differences were observed in preoperative P-wave parameters as Maximum P Wave Duration(Pmax), absolute value of P Wave Terminal Force of V1 (PtfV1) and P Wave Dispersion(Pd), postoperative P-wave parameters as P Wave Duration (PWDII, III, aVF), Pmax, P Wave Area(P-area), absolute value of PtfV1 and Pd, and changes in perioperative P-wave parameters (Delta-Pmax, Delta-PtfV1 absolute value, Delta-Pd, Delta-PWDII, III, aVF). Univariate logistic regression, receiver operating characteristic (ROC) curve analysis, and hazard ratio assessment identified predictive indicators for postoperative recurrence, including Pmax, PtfV1 absolute value, Pd, post-P area, post-PWDII, III, aVF and Delta-pwdII, III, aVF). A personalized nomogram model based on these P-wave parameters was developed. Calibration curve assessment demonstrated that the predictive performance of the nomogram for PAF recurrence following catheter ablation closely matched actual observed outcomes. ROC curve analysis indicated a sensitivity of 89.3% for the model, and decision curve analysis confirmed its significantly favorable predictive use and clinical benefits. CONCLUSIONS: P-wave parameters like PWDШ, PWDaVF, Pmax, Pd, and PtfV1 serve as predictors of PAF recurrence following catheter ablation. The nomogram model constructed using these P-wave parameters demonstrates robust predictive performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular Disease, F…
- Department of Electrocardiography, Fujian Provincial Governmental Hospital, Fuzhou, 350001, China.
Zitieren
APA
Yu, L. J., Chen, X. H., Xu, Z., Gong, K. Z., & Zhang, F. L. (2025). A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation. Journal of Cardiothoracic Surgery. https://doi.org/10.1186/s13019-024-03335-0
Vancouver
Yu LJ, Chen XH, Xu Z, Gong KZ, Zhang FL. A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation. Journal of Cardiothoracic Surgery. 2025. doi:10.1186/s13019-024-03335-0
BibTeX
@article{Yu2025,
author = {Yu, Li-Juan and Chen, Xue-Hai and Xu, Zhe and Gong, Ke-Zeng and Zhang, Fei-Long},
title = {A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation},
journal = {Journal of Cardiothoracic Surgery},
year = {2025},
doi = {10.1186/s13019-024-03335-0}
}
EUVIMED