Towards an anthropomorphic MRI phantom mimicking static and dynamic B0 field variations in the human cervical spinal cord
Magnetic Resonance Materials in Physics, Biology and Medicine · 15.04.2026 · 39 (5) · 877-895
DOI: 10.1007/s10334-026-01349-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 15.04.2026. Verfasst von Laura Beghini und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Cervical Cord, Cervical Vertebrae. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NTNU Norwegian University of Science and Technology.
Abstract (Originalsprache)
Objective
Spinal cord MRI is heavily affected by static and dynamic B 0 field variations. The aim of this study was to develop an anthropomorphic cervical spine phantom that replicates these. Materials and Methods The phantom consisted of a 3D-printed head-to-thorax shell containing 3D-printed vertebrae (C1–T1) in a water-based liquid solution. An external respiration system mimicked breathing-induced field fluctuations by moving metal staples over the phantom. The accuracy of the reproduced fields was evaluated at 7 T by field maps and multi-echo GREs acquired in the phantom and in four subjects.
Results
Fourier-based field simulations confirmed the vertebrae to be the main contributors to the local static field in the spinal canal, providing a rationale for the phantom design. The 3D-printed vertebrae accurately reproduced the spatial field pattern encountered in vivo, but with one-third of the intensity due to lower susceptibility differences. The respiration system produced spatially and temporally similar dynamic field fluctuations as in vivo.
Discussion
The phantom was designed to be low-cost, modular and reproducible, while also being non-toxic and free from biological hazards. It may serve as a useful tool for development and testing of correction strategies to address the persistent challenge of B 0 field variations in spinal cord MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway.
- CRCI2NA, INSERM UMR 1307, Nantes, France.
- Nuclear Medicine Department, University Hospital, Nantes, France.
- Aix-Marseille Université, CNRS, CRMBM UMR 7339, Marseille, France.
- AP-HM, Hopital de La Timone, Pôle d'imagerie Médicale, CEMEREM, Marseille, France.
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway. johanna.vannesjo@ntnu.no.
Förderung
- NTNU Norwegian University of Science and Technology
Zitieren
APA
Beghini, L., Ponsi, B. M. A., Refsholt, K., Schmidt, A. D., Callot, V., & Vannesjo, S. J. (2026). Towards an anthropomorphic MRI phantom mimicking static and dynamic B0 field variations in the human cervical spinal cord. Magnetic Resonance Materials in Physics, Biology and Medicine, 39(5), 877-895. https://doi.org/10.1007/s10334-026-01349-4
Vancouver
Beghini L, Ponsi BMA, Refsholt K, Schmidt AD, Callot V, Vannesjo SJ. Towards an anthropomorphic MRI phantom mimicking static and dynamic B0 field variations in the human cervical spinal cord. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026;39(5):877-895. doi:10.1007/s10334-026-01349-4
BibTeX
@article{Beghini2026,
author = {Beghini, Laura and Ponsi, Brunnhilde M A-S and Refsholt, Kamilla and Schmidt, Annelen Dogger and Callot, Virginie and Vannesjo, S Johanna},
title = {Towards an anthropomorphic MRI phantom mimicking static and dynamic B0 field variations in the human cervical spinal cord},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2026},
volume = {39},
number = {5},
pages = {877--895},
doi = {10.1007/s10334-026-01349-4}
}
EUVIMED