3D Printing of Subject‐Specific Passive Shims for In Vivo Small‐Animal Magnetic Resonance Imaging
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70520 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von An Vanduffel und 8 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Membrane Separations, Adsorption, Catalysis and Spectroscopy (cMACS), KU Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Printing, Three-Dimensional, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Fonds Wetenschappelijk Onderzoek, KU Leuven, Agentschap Innoveren en Ondernemen.
Abstract (Originalsprache)
Purpose
Magnetic resonance imaging (MRI) is a non‐invasive method that relies on a highly homogeneous B 0 magnetic field to generate high‐quality images. However, subject‐specific inhomogeneities, induced by magnetic susceptibility differences, can degrade image quality and cause artifacts and are often inadequately corrected by traditional active or passive shimming methods. This work aims to create a new passive shimming method to overcome these problems.
Method
This study introduces an innovative approach to developing custom, subject‐specific passive shims 3D‐printed with a binder and a ferromagnetic ink. The optimal spatial distribution and concentration of ferromagnetic material within the shim are calculated using a custom algorithm that minimizes the magnetic field standard deviation.
Results
The shim design and fabrication process is demonstrated for in vivo passive shimming of a rat brain, yielding a 21% improvement in magnetic field homogeneity and improved image quality in spin‐echo echo‐planar imaging scans, with a 65% increase in the Dice‐Sørensen similarity coefficient.
Conclusion
This approach highlights the potential of combining computational optimization with additive manufacturing for effective, subject‐specific passive shimming in MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Membrane Separations, Adsorption, Catalysis and Spectroscopy (cMACS), KU Leuven, Leuven, Belgium.
- Biomedical MRI, Department of Imaging & Pathology, KU Leuven, Leuven, Belgium.
ORCID-Profile: An Vanduffel, Uwe Himmelreich
Förderung
- Fonds Wetenschappelijk Onderzoek
- KU Leuven
- Agentschap Innoveren en Ondernemen
Zitieren
APA
Vanduffel, A., Parra-Cabrera, C., Vanduffel, H., Goudard, Q., Błażejczyk, K., Helsper, S., Himmelreich, U., Sakellariou, D., & Ameloot, R. (2026). 3D Printing of Subject‐Specific Passive Shims for In Vivo Small‐Animal Magnetic Resonance Imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70520
Vancouver
Vanduffel A, Parra-Cabrera C, Vanduffel H, Goudard Q, Błażejczyk K, Helsper S, et al. 3D Printing of Subject‐Specific Passive Shims for In Vivo Small‐Animal Magnetic Resonance Imaging. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70520
BibTeX
@article{Vanduffel2026,
author = {Vanduffel, An and Parra-Cabrera, Cesar and Vanduffel, Hanne and Goudard, Quentin and Błażejczyk, Kasia and Helsper, Shannon and Himmelreich, Uwe and Sakellariou, Dimitrios and Ameloot, Rob},
title = {3D Printing of Subject‐Specific Passive Shims for In Vivo Small‐Animal Magnetic Resonance Imaging},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70520}
}
EUVIMED