Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 05.03.2026. Verfasst von Pauline Calarnou und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Lausanne University Hospital and University of Lausanne, CHUV BH, 08/084, Rue du Bugnon 46, 1011, Lausanne, Switzerland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Kidney. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To develop and evaluate a free-breathing 2D radial joint T₁–T₂ mapping technique for the kidneys at 3T, and to assess the impact of navigator gating parameters on mapping accuracy in a phantom and precision in healthy volunteers.

Methods

The PARMANav sequence (PArametric Radial MApping with Navigator gating) was implemented with 25 single-shot radial gradient-echo acquisitions with five magnetization preparations and lung-liver navigator gating to avoid through-plane motion. Images were reconstructed using region-optimized virtual coils and compressed sensing, followed by model-based registration. An acquisition-specific joint T₁–T₂ dictionary was generated using extended phase-graph simulations. T 1 –T 2 accuracy was quantified in a phantom and T 1 –T 2 precision was established in 10 healthy volunteers. Three patients were scanned to demonstrate clinical feasibility.

Results

In the phantom, PARMANav T 1 –T 2 accuracy was high and insensitive to rejected navigators (< 5% variation for T 1 and T 2 ). In vivo PARMANav T 1 and T 2 values were higher than routine values but less variable, both per subject and between subjects: cortex PARMANav T 1 = 1601 ± 48 ms/T 2 = 90.8 ± 5.0 ms vs routine T 1 = 1307 ± 108 ms/T 2 = 73.3 ± 8.0 ms, medulla PARMANav T 1 = 2044 ± 82 ms/T 2 = 90.3 ± 5.4 ms and routine T 1 = 1560 ± 122 ms/T 2 = 67.6 ± 5.8 ms. No T 1 or T 2 trend was observed for the different NAWW. High-quality maps were obtained in the patients.

Conclusion

With accuracy confirmed in the phantom study and precision demonstrated in volunteers, PARMANav allows for precise and accurate renal joint T 1 –T 2 mapping during free-breathing while minimizing through-plane motion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingKidneyHumansPhantoms, ImagingRespirationFemaleAdultMaleAlgorithmsReproducibility of ResultsImage Processing, Computer-AssistedHealthy VolunteersImage Interpretation, Computer-AssistedMiddle Aged

Stichwörter der Autor:innen

Dictionary fittingFree breathingKidneyMagnetic resonance imagingParametric mapping

Autor:innen und Institutionen

  • Department of Radiology, Lausanne University Hospital and University of Lausanne, CHUV BH, 08/084, Rue du Bugnon 46, 1011, Lausanne, Switzerland.
  • CIBM Center for BioMedical Imaging, Lausanne, Geneva, Switzerland.
  • Department of Cardiology Service, Cardiovascular, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Department of Nephrology Service, Internal Medicine, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Radiology Service, Department of Diagnostics, Geneva University Hospital and University of Geneva, Geneva, Switzerland.
  • Department of Radiology, Lausanne University Hospital and University of Lausanne, CHUV BH, 08/084, Rue du Bugnon 46, 1011, Lausanne, Switzerland. ruud.mri@gmail.com.

Förderung

  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Calarnou, P., Ogier, A. C., Roy, C. W., Ledoux, J. B., Rocca, A., Rapacchi, S., Pruijm, M., Hullin, R., Vallée, J. P., Yerly, J., & van Heeswijk, R. B. (2026). Navigator-gated free-breathing joint T1–T2 mapping of the kidney. Magnetic Resonance Materials in Physics, Biology and Medicine, 39(5), 751-763. https://doi.org/10.1007/s10334-026-01337-8

Vancouver

Calarnou P, Ogier AC, Roy CW, Ledoux JB, Rocca A, Rapacchi S, et al. Navigator-gated free-breathing joint T1–T2 mapping of the kidney. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026;39(5):751-763. doi:10.1007/s10334-026-01337-8

BibTeX
@article{Calarnou2026,
  author = {Calarnou, Pauline and Ogier, Augustin C and Roy, Christopher W and Ledoux, Jean-Baptiste and Rocca, Angela and Rapacchi, Stanislas and Pruijm, Menno and Hullin, Roger and Vallée, Jean-Paul and Yerly, Jérôme and van Heeswijk, Ruud B},
  title = {Navigator-gated free-breathing joint T1–T2 mapping of the kidney},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2026},
  volume = {39},
  number = {5},
  pages = {751--763},
  doi = {10.1007/s10334-026-01337-8}
}
Kostenlos starten →