EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous whole‐liver water T1 and T2 mapping with isotropic resolution during free‐breathing

Jonathan Stelter iD, Kilian Weiss, Lisa Steinhelfer, Veronika Spieker, Elizabeth Huaroc Moquillaza, Weitong Zhang, Marcus R Makowski, Julia A Schnabel, Bernhard Kainz, Rickmer F Braren, Dimitrios C Karampinos

NMR in Biomedicine · 2024-12 · 37 (12)

DOI: 10.1002/nbm.5216 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 04.08.2024. Verfasst von Jonathan Stelter und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Liver, Respiration, Phantoms, Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Philips Healthcare, TUM International Graduate School of Science and Engineering, Philips.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop and validate a data acquisition scheme combined with a motion‐resolved reconstruction and dictionary‐matching‐based parameter estimation to enable free‐breathing isotropic resolution self‐navigated whole‐liver simultaneous water‐specific ( ) and ( ) mapping for the characterization of diffuse and oncological liver diseases.

Methods

The proposed data acquisition consists of a magnetization preparation pulse and a two‐echo gradient echo readout with a radial stack‐of‐stars trajectory, repeated with different preparations to achieve different and contrasts in a fixed acquisition time of 6 min. Regularized reconstruction was performed using self‐navigation to account for motion during the free‐breathing acquisition, followed by water–fat separation. Bloch simulations of the sequence were applied to optimize the sequence timing for insensitivity at 3 T, to correct for relaxation‐induced blurring, and to map and using a dictionary. The proposed method was validated on a water–fat phantom with varying relaxation properties and in 10 volunteers against imaging and spectroscopy reference values. The performance and robustness of the proposed method were evaluated in five patients with abdominal pathologies.

Results

Simulations demonstrate good insensitivity of the proposed method in measuring and values. The proposed method produces co‐registered and maps with a good agreement with reference methods (phantom: ; ). The proposed and mapping exhibits good repeatability and can be robustly performed in patients with pathologies.

Conclusions

The proposed method allows whole‐liver and quantification with high accuracy at isotropic resolution in a fixed acquisition time during free‐breathing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverRespirationPhantoms, ImagingMagnetic Resonance ImagingHumansAdultMaleFemaleMiddle AgedBody WaterReproducibility of ResultsAnisotropyWater

Stichwörter der Autor:innen

BIR‐4 preparationdictionary matchingradial stack‐of‐starsrelaxometrywater–fat separation

Substanzen

Water

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany.
  • Philips GmbH Market DACH, Hamburg, Germany.
  • Institute of Machine Learning for Biomedical Imaging, Helmholtz Munich, Neuherberg, Germany.
  • School of Computation, Information and Technology, Technical University of Munich, Munich, Germany.
  • Department of Computing, Imperial College London, London, United Kingdom.
  • School of Biomedical Imaging and Imaging Sciences, King's College London, London, United Kingdom.

ORCID-Profile: Jonathan Stelter

Förderung

  • Philips Healthcare
  • TUM International Graduate School of Science and Engineering
  • Philips
  • International Graduate School of Science and Engineering

Zitieren

APA

Stelter, J., Weiss, K., Steinhelfer, L., Spieker, V., Huaroc Moquillaza, E., Zhang, W., Makowski, M. R., Schnabel, J. A., Kainz, B., Braren, R. F., & Karampinos, D. C. (2024). Simultaneous whole‐liver water T1 and T2 mapping with isotropic resolution during free‐breathing. NMR in Biomedicine, 37(12). https://doi.org/10.1002/nbm.5216

Vancouver

Stelter J, Weiss K, Steinhelfer L, Spieker V, Huaroc Moquillaza E, Zhang W, et al. Simultaneous whole‐liver water T1 and T2 mapping with isotropic resolution during free‐breathing. NMR in Biomedicine. 2024;37(12). doi:10.1002/nbm.5216

BibTeX
@article{Stelter2024,
  author = {Stelter, Jonathan and Weiss, Kilian and Steinhelfer, Lisa and Spieker, Veronika and Huaroc Moquillaza, Elizabeth and Zhang, Weitong and Makowski, Marcus R and Schnabel, Julia A and Kainz, Bernhard and Braren, Rickmer F and Karampinos, Dimitrios C},
  title = {Simultaneous whole‐liver water T1 and T2 mapping with isotropic resolution during free‐breathing},
  journal = {NMR in Biomedicine},
  year = {2024},
  volume = {37},
  number = {12},
  doi = {10.1002/nbm.5216}
}
Kostenlos starten →