Multi-center QA of ultrahigh-field systems

Oliver Kraff, Markus W May

Magnetic Resonance Materials in Physics, Biology and Medicine · 2025

DOI: 10.1007/s10334-025-01232-8 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von Oliver Kraff und 1 weiteren Autor:innen. Beteiligte Einrichtung: Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, Kokereiallee 7, 45141, Essen, Germany. oliver.kraff@web.de. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Essen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past two decades, ultra-high field (UHF) magnetic resonance imaging (MRI) has evolved from pure investigational devices to now systems with CE and FDA clearance for clinical use. UHF MRI offers enhanced diagnostic value, especially in brain and musculoskeletal imaging, aiding in the differential diagnosis of conditions like multiple sclerosis and epilepsy. However, to fully harness the potential of UHF, multi-center studies and quality assurance (QA) protocols are critical for ensuring reproducibility across different systems and sites. This becomes even more vital as the UHF community comprises three generations of magnet design, and many UHF sites are currently upgrading to the latest system architecture. Hence, this review presents multi-center QA measurements that have been performed at UHF, in particular from larger consortia through their “travelling heads” studies. Despite the technical variability between different vendors and system generations, these studies have shown a high level of reproducibility in structural and quantitative imaging. Furthermore, the review highlights the ongoing challenges in QA, such as transmitter performance drift and the need for a standard reliable multi-tissue phantom for RF coil calibration, which are crucial for advancing UHF MRI in both clinical and research applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHumansReproducibility of ResultsPhantoms, ImagingCalibrationEquipment DesignBrainQuality Assurance, Health CareQuality ControlImage Processing, Computer-AssistedMultiple SclerosisMulticenter Studies as Topic

Stichwörter der Autor:innen

7 Tesla (7 T)Multi-centerQuality assurance (QA)Ultra-high field (UHF) MRI

Autor:innen und Institutionen

  • Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, Kokereiallee 7, 45141, Essen, Germany. oliver.kraff@web.de.
  • Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, Kokereiallee 7, 45141, Essen, Germany.
  • High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany.

Förderung

  • Universitätsklinikum Essen

Zitieren

APA

Kraff, O., & May, M. W. (2025). Multi-center QA of ultrahigh-field systems. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01232-8

Vancouver

Kraff O, May MW. Multi-center QA of ultrahigh-field systems. Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01232-8

BibTeX
@article{Kraff2025,
  author = {Kraff, Oliver and May, Markus W},
  title = {Multi-center QA of ultrahigh-field systems},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2025},
  doi = {10.1007/s10334-025-01232-8}
}