EUVIMEDEUVIMED entdecken
Open Access

DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI

Ouri Cohen, Soudabeh Kargar, Sungmin Woo, Alberto Vargas, Ricardo Otazo

Magnetic Resonance Materials in Physics, Biology and Medicine · 2024

DOI: 10.1007/s10334-024-01189-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2024. Verfasst von Ouri Cohen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 320 East 61st St 10025, USA. coheno1@mskcc.org. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Contrast Media, Uterine Cervical Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Cancer Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. METHODS: A 7-layer neural network called DCE-Qnet was trained on simulated DCE-MRI signals derived from the Extended Tofts model with the Parker arterial input function. Network training incorporated B1 inhomogeneities to estimate perfusion (Ktrans, vp, ve), tissue T1 relaxation, proton density and bolus arrival time (BAT). The accuracy was tested in a digital phantom in comparison to a conventional nonlinear least-squares fitting (NLSQ). In vivo testing was conducted in ten healthy subjects. Regions of interest in the cervix and uterine myometrium were used to calculate the inter-subject variability. The clinical utility was demonstrated on a cervical cancer patient. Test-retest experiments were used to assess reproducibility of the parameter maps in the tumor. RESULTS: The DCE-Qnet reconstruction outperformed NLSQ in the phantom. The coefficient of variation (CV) in the healthy cervix varied between 5 and 51% depending on the parameter. Parameter values in the tumor agreed with previous studies despite differences in methodology. The CV in the tumor varied between 1 and 47%. CONCLUSION: The proposed approach provides comprehensive DCE-MRI quantification from a single acquisition. DCE-Qnet eliminates the need for separate T1 scan or BAT processing, leading to a reduction of 10 min per scan and more accurate quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingContrast MediaUterine Cervical NeoplasmsNeural Networks, ComputerImage Processing, Computer-AssistedHumansFemaleReproducibility of ResultsAdultCervix UteriHealthy VolunteersLeast-Squares AnalysisAlgorithmsImage EnhancementDeep Learning

Stichwörter der Autor:innen

DCEDRONEDeep learningNeural network

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 320 East 61st St 10025, USA. coheno1@mskcc.org.
  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 320 East 61st St 10025, USA.
  • Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.

Förderung

  • NCI NIH HHS
  • National Cancer Institute

Zitieren

APA

Cohen, O., Kargar, S., Woo, S., Vargas, A., & Otazo, R. (2024). DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-024-01189-0

Vancouver

Cohen O, Kargar S, Woo S, Vargas A, Otazo R. DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. 2024. doi:10.1007/s10334-024-01189-0

BibTeX
@article{Cohen2024,
  author = {Cohen, Ouri and Kargar, Soudabeh and Woo, Sungmin and Vargas, Alberto and Otazo, Ricardo},
  title = {DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2024},
  doi = {10.1007/s10334-024-01189-0}
}
Kostenlos starten →