Optimized Magnetic Resonance T1 Mapping for Estimation of Intrathecal Contrast Concentrations in Human Brain and Ventricular Cerebrospinal Fluid
Magnetic Resonance in Medicine · 2026-04 · 95 (4) · 2169-2179
DOI: 10.1002/mrm.70203 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 03.12.2025. Verfasst von Lars Magnus Valnes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Oslo University Hospital - Rikshospitalet, Oslo, Norway. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Imaging, Brain, Cerebrospinal Fluid. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Helse Sør-Øst RHF, Wellcome Trust, Stiftelsen Kristian Gerhard Jebsen.
Abstract (Originalsprache)
Purpose
Intrathecal contrast‐enhanced magnetic resonance imaging (MRI), which uses a contrast agent as a cerebrospinal fluid (CSF) tracer, is an emerging technique for in vivo imaging of glymphatic function in humans. T1 mapping enables quantification of tracer concentrations; however, methodological limitations persist. This study aimed to enhance the utility of a standard Look‐Locker MRI sequence for quantifying tracer concentrations in both brain parenchyma and ventricular CSF.
Methods
Using a 3 T MRI scanner, we conducted (i) optimization of a Look‐Locker T1 mapping protocol to determine T1 relaxation times in brain parenchyma and ventricular CSF, (ii) a phantom study to assess repeatability of T1 times estimation and the relaxivity constant r 1 calculation, and (iii) a feasibility assessment in patients.
Results
An optimized Look‐Locker protocol for T1 mapping enabled estimation of T1 relaxation times in brain parenchyma and ventricular CSF that compare with previously reported T1 times. The phantom study demonstrated repeatability of T1 time estimations. In six patients with idiopathic normal pressure hydrocephalus, the method proved feasible for estimating CSF tracer concentrations in brain and ventricular CSF over time following intrathecal MRI contrast injection (gadobutrol, 0.5 mmol).
Conclusion
Optimizing a standard Look‐Locker T1 mapping protocol allowed for estimation of reliable T1 times in both brain parenchyma and ventricular CSF, and the subsequent determination of concentrations of intrathecal CSF tracer in the human brain, supporting its potential for studying glymphatic function. However, limitations with estimation of T1 times and the selection of relaxivity constant of the contrast agent reduce accuracy of concentration estimates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurosurgery, Oslo University Hospital - Rikshospitalet, Oslo, Norway.
- Department of Mathematics, University of Oslo, Oslo, Norway.
- Department of Physics and Computational Radiology, Division of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway.
- KG Jebsen Centre for Brain Fluid Research, University Oslo, Oslo, Norway.
- The Intervention Centre, Oslo University Hospital - Rikshospitalet, Oslo, Norway.
- Department of Health Sciences Gjøvik, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Gjøvik, Norway.
Förderung
- Helse Sør-Øst RHF
- Wellcome Trust
- Stiftelsen Kristian Gerhard Jebsen
- Norges Forskningsråd
Zitieren
APA
Valnes, L. M., Storås, T. H., Vatnehol, S. A. S., Ringstad, G., Emblem, K. E., & Eide, P. K. (2026). Optimized Magnetic Resonance T1 Mapping for Estimation of Intrathecal Contrast Concentrations in Human Brain and Ventricular Cerebrospinal Fluid. Magnetic Resonance in Medicine, 95(4), 2169-2179. https://doi.org/10.1002/mrm.70203
Vancouver
Valnes LM, Storås TH, Vatnehol SAS, Ringstad G, Emblem KE, Eide PK. Optimized Magnetic Resonance T1 Mapping for Estimation of Intrathecal Contrast Concentrations in Human Brain and Ventricular Cerebrospinal Fluid. Magnetic Resonance in Medicine. 2026;95(4):2169-2179. doi:10.1002/mrm.70203
BibTeX
@article{Valnes2026,
author = {Valnes, Lars Magnus and Storås, Trygve Holck and Vatnehol, Svein Are Sirirud and Ringstad, Geir and Emblem, Kyrre Eeg and Eide, Per Kristian},
title = {Optimized Magnetic Resonance T1 Mapping for Estimation of Intrathecal Contrast Concentrations in Human Brain and Ventricular Cerebrospinal Fluid},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {4},
pages = {2169--2179},
doi = {10.1002/mrm.70203}
}
EUVIMED