EUVIMEDEUVIMED entdecken
Crossref

Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants

Noam Ben-Eliezer, Eddy Solomon, Elad Harel, Nava Nevo, Lucio Frydman

Magnetic Resonance Materials in Physics, Biology and Medicine · 2012-12 · 25 (6) · 433-442

DOI: 10.1007/s10334-012-0318-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 29.06.2012. Verfasst von Noam Ben-Eliezer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Physics Department, Weizmann Institute of Science, 76100 Rehovot, Israel. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECT: An approach has been recently introduced for acquiring arbitrary 2D NMR spectra or images in a single scan, based on the use of frequency-swept RF pulses for the sequential excitation and acquisition of the spins response. This spatiotemporal-encoding (SPEN) approach enables a unique, voxel-by-voxel refocusing of all frequency shifts in the sample, for all instants throughout the data acquisition. The present study investigates the use of this full-refocusing aspect of SPEN-based imaging in the multi-shot MRI of objects, subject to sizable field inhomogeneities that complicate conventional imaging approaches. MATERIALS AND METHODS: 2D MRI experiments were performed at 7 T on phantoms and on mice in vivo, focusing on imaging in proximity to metallic objects. Fully refocused SPEN-based spin echo imaging sequences were implemented, using both Cartesian and back-projection trajectories, and compared with k-space encoded spin echo imaging schemes collected on identical samples under equal bandwidths and acquisition timing conditions. RESULTS: In all cases assayed, the fully refocused spatiotemporally encoded experiments evidenced a ca. 50 % reduction in signal dephasing in the proximity of the metal, as compared to analogous results stemming from the k-space encoded spin echo counterparts. CONCLUSION: The results in this study suggest that SPEN-based acquisition schemes carry the potential to overcome strong field inhomogeneities, of the kind that currently preclude high-field, high-resolution tissue characterizations in the neighborhood of metallic implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsAnimalsCalibrationEcho-Planar ImagingImage Processing, Computer-AssistedMagnetic Resonance ImagingMagnetic Resonance SpectroscopyMetalsMiceMice, SCIDModels, StatisticalPhantoms, ImagingProstheses and ImplantsReproducibility of ResultsSoftware

Substanzen

Metals

Autor:innen und Institutionen

  • Chemical Physics Department, Weizmann Institute of Science, 76100 Rehovot, Israel.

Zitieren

APA

Ben-Eliezer, N., Solomon, E., Harel, E., Nevo, N., & Frydman, L. (2012). Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants. Magnetic Resonance Materials in Physics, Biology and Medicine, 25(6), 433-442. https://doi.org/10.1007/s10334-012-0318-7

Vancouver

Ben-Eliezer N, Solomon E, Harel E, Nevo N, Frydman L. Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants. Magnetic Resonance Materials in Physics, Biology and Medicine. 2012;25(6):433-442. doi:10.1007/s10334-012-0318-7

BibTeX
@article{BenEliezer2012,
  author = {Ben-Eliezer, Noam and Solomon, Eddy and Harel, Elad and Nevo, Nava and Frydman, Lucio},
  title = {Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2012},
  volume = {25},
  number = {6},
  pages = {433--442},
  doi = {10.1007/s10334-012-0318-7}
}
Kostenlos starten →