Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants
Magnetic Resonance Materials in Physics, Biology and Medicine · 2012-12 · 25 (6) · 433-442
DOI: 10.1007/s10334-012-0318-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 29.06.2012. Verfasst von Noam Ben-Eliezer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Physics Department, Weizmann Institute of Science, 76100 Rehovot, Israel. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
OBJECT: An approach has been recently introduced for acquiring arbitrary 2D NMR spectra or images in a single scan, based on the use of frequency-swept RF pulses for the sequential excitation and acquisition of the spins response. This spatiotemporal-encoding (SPEN) approach enables a unique, voxel-by-voxel refocusing of all frequency shifts in the sample, for all instants throughout the data acquisition. The present study investigates the use of this full-refocusing aspect of SPEN-based imaging in the multi-shot MRI of objects, subject to sizable field inhomogeneities that complicate conventional imaging approaches. MATERIALS AND METHODS: 2D MRI experiments were performed at 7 T on phantoms and on mice in vivo, focusing on imaging in proximity to metallic objects. Fully refocused SPEN-based spin echo imaging sequences were implemented, using both Cartesian and back-projection trajectories, and compared with k-space encoded spin echo imaging schemes collected on identical samples under equal bandwidths and acquisition timing conditions. RESULTS: In all cases assayed, the fully refocused spatiotemporally encoded experiments evidenced a ca. 50 % reduction in signal dephasing in the proximity of the metal, as compared to analogous results stemming from the k-space encoded spin echo counterparts. CONCLUSION: The results in this study suggest that SPEN-based acquisition schemes carry the potential to overcome strong field inhomogeneities, of the kind that currently preclude high-field, high-resolution tissue characterizations in the neighborhood of metallic implants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Chemical Physics Department, Weizmann Institute of Science, 76100 Rehovot, Israel.
Zitieren
APA
Ben-Eliezer, N., Solomon, E., Harel, E., Nevo, N., & Frydman, L. (2012). Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants. Magnetic Resonance Materials in Physics, Biology and Medicine, 25(6), 433-442. https://doi.org/10.1007/s10334-012-0318-7
Vancouver
Ben-Eliezer N, Solomon E, Harel E, Nevo N, Frydman L. Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants. Magnetic Resonance Materials in Physics, Biology and Medicine. 2012;25(6):433-442. doi:10.1007/s10334-012-0318-7
BibTeX
@article{BenEliezer2012,
author = {Ben-Eliezer, Noam and Solomon, Eddy and Harel, Elad and Nevo, Nava and Frydman, Lucio},
title = {Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2012},
volume = {25},
number = {6},
pages = {433--442},
doi = {10.1007/s10334-012-0318-7}
}
EUVIMED