Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction

Huan Zhang, Yue Xing, Lingyun Wang, Yangfan Hu, Zhihan Xu, Haoda Chen, Junjie Lu, Jiarui Yang, Bei Ding, Weiguo Hu, Jingyu Zhong

Journal of Imaging Informatics in Medicine · 25.10.2024 · 38 (3) · 1891-1903

DOI: 10.1007/s10278-024-01232-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Imaging Informatics in Medicine, online erschienen am 25.10.2024. Verfasst von Huan Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Abdomen, Image Processing, Computer-Assisted, Tomography, X-Ray Computed. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Yangfan Project of Science and Technology Commission of Shanghai Municipality, Research Found of Health Commission of Changing District, Shanghai Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to investigate the potential benefit of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) angiography in visualization of abdominal arteries in comparison to standard-reconstruction (SR) images of virtual monoenergetic images (VMI) at low kiloelectron volt (keV). We prospectively included 47 and 47 participants to undergo contrast-enhanced abdominal CT scans within UHR mode on a PCD-CT system using full-dose (FD) and low-dose (LD) protocols, respectively. The data were reconstructed into six series of images: FD_UHR_Br48, FD_UHR_Bv56, FD_UHR_Bv60, FD_SR_Bv40, LD_UHR_Bv48, and LD_SR_Bv40. The UHR reconstructions were performed with three kernels (Bv48, Bv56, and Bv60) within 0.2 mm. The SR were virtual monoenergetic imaging reconstruction with Bv40 kernel at 40-keV within 1 mm. Each series of axial images were reconstructed into coronal and volume-rendered images. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of seven arteries were measured. Three radiologists assessed the image quality, and visibility of nine arteries on all the images. SNR and CNR values of SR images were significantly higher than those of UHR images ( P < 0.001). The SR images have higher ratings in image noise ( P < 0.001), but the FD_UHR_Bv56 and FD_UHR_Bv60 images has higher rating in vessel sharpness ( P < 0.001). The overall quality was not significantly different among FD_VMI_40keV, LD_VMI_40keV, FD_UHR_Bv48, and LD_UHR_Bv48 images ( P > 0.05) but higher than those of FD_UHR_Bv56 and FD_UHR_Bv60 images ( P < 0.001). There is no significant difference of nine abdominal arteries among six series of images of axial, coronal and volume-rendered images ( P > 0.05). To conclude, 1-mm SR image of VMI at 40-keV is superior to 0.2-mm UHR regardless of which kernel is used to visualize abdominal arteries, while 0.2-mm UHR image using a relatively smooth kernel may allow similar image quality and artery visibility when thinner slice image is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyAbdomenImage Processing, Computer-AssistedTomography, X-Ray ComputedRadiographic Image Interpretation, Computer-AssistedRadiography, AbdominalHumansMaleFemaleMiddle AgedProspective StudiesPhotonsAdultAgedRadiation DosageContrast Media

Stichwörter der Autor:innen

Computed tomography angiographyContrast mediaImage enhancementImage reconstructionRadiation dosage

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
  • Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
  • Siemens Healthineers, Shanghai, 201318, China.
  • Department of General Surgery, Pancreatic Disease Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
  • Department of Epidemiology and Population Health, Stanford University School of Medicine, Stanford, CA, 94305, USA.
  • Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA.

Förderung

  • National Natural Science Foundation of China
  • Yangfan Project of Science and Technology Commission of Shanghai Municipality
  • Research Found of Health Commission of Changing District, Shanghai Municipality
  • Laboratory Open Fund of Key Technology and Materials in Minimally Invasive Spine Surgery
  • Research Fund of Tongren Hospital, Shanghai Jiao Tong University School of Medicine

Zitieren

APA

Zhang, H., Xing, Y., Wang, L., Hu, Y., Xu, Z., Chen, H., Lu, J., Yang, J., Ding, B., Hu, W., & Zhong, J. (2024). Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction. Journal of Imaging Informatics in Medicine, 38(3), 1891-1903. https://doi.org/10.1007/s10278-024-01232-5

Vancouver

Zhang H, Xing Y, Wang L, Hu Y, Xu Z, Chen H, et al. Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction. Journal of Imaging Informatics in Medicine. 2024;38(3):1891-1903. doi:10.1007/s10278-024-01232-5

BibTeX
@article{Zhang2024,
  author = {Zhang, Huan and Xing, Yue and Wang, Lingyun and Hu, Yangfan and Xu, Zhihan and Chen, Haoda and Lu, Junjie and Yang, Jiarui and Ding, Bei and Hu, Weiguo and Zhong, Jingyu},
  title = {Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2024},
  volume = {38},
  number = {3},
  pages = {1891--1903},
  doi = {10.1007/s10278-024-01232-5}
}
Kostenlos starten →