EUVIMEDEUVIMED entdecken
Vergleichsstudie

Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement

Milán Vecsey-Nagy iD, Giuseppe Tremamunno iD, U Joseph Schoepf iD, Chiara Gnasso iD, Emese Zsarnóczay iD, Nicola Fink, Dmitrij Kravchenko iD, Moritz C Halfmann, Gerald S Laux, Jim O'Doherty iD, Bálint Szilveszter iD, Pál Maurovich-Horvat iD und 4 weitere

Circulation: Cardiovascular Imaging · 2024-10 · 17 (10)

DOI: 10.1161/circimaging.124.017112 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Circulation: Cardiovascular Imaging, 2024-10. Verfasst von Milán Vecsey-Nagy und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston (M.V.-N., G.T., U.J.S., C.G., E.Z., N.F., D.K., J.…. Hauptthemen laut MEDLINE: Coronary Stenosis, Coronary Angiography, Computed Tomography Angiography. Die Arbeit wurde bisher 64-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary StenosisCoronary AngiographyComputed Tomography AngiographyHumansMaleFemaleProspective StudiesMiddle AgedAgedReproducibility of ResultsPredictive Value of TestsCoronary VesselsPhotonsSeverity of Illness IndexVascular Calcification

Stichwörter der Autor:innen

computed tomography angiographycoronary angiographycoronary artery diseasecoronary stenosis

Autor:innen und Institutionen

  • Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston (M.V.-N., G.T., U.J.S., C.G., E.Z., N.F., D.K., J.O.D., I.M.K., P.S.S., A.V.-S., T.E.).
  • Heart and Vascular Center, Semmelweis University, Budapest, Hungary (M.V.-N., B.S.).
  • Radiology Unit, Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Italy (G.T.).
  • Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Milan, Italy (C.G.).
  • MTA-SE Cardiovascular Imaging Research Group, Department of Radiology, Medical Imaging Centre, Semmelweis University, Budapest, Hungary (E.Z., P.M.-H.).
  • Department of Radiology, University Hospital, LMU Munich, Germany (N.F.).

ORCID-Profile: Milán Vecsey-Nagy, Giuseppe Tremamunno, U Joseph Schoepf, Chiara Gnasso, Emese Zsarnóczay, Dmitrij Kravchenko, Jim O'Doherty, Bálint Szilveszter, Pál Maurovich-Horvat, Ismail Mikdat Kabakus, Akos Varga-Szemes, Tilman Emrich

Zitieren

APA

Vecsey-Nagy, M., Tremamunno, G., Schoepf, U. J., Gnasso, C., Zsarnóczay, E., Fink, N., Kravchenko, D., Halfmann, M. C., Laux, G. S., O'Doherty, J., Szilveszter, B., Maurovich-Horvat, P., Kabakus, I. M., Suranyi, P. S., Varga-Szemes, A., & Emrich, T. (2024). Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement. Circulation: Cardiovascular Imaging, 17(10). https://doi.org/10.1161/circimaging.124.017112

Vancouver

Vecsey-Nagy M, Tremamunno G, Schoepf UJ, Gnasso C, Zsarnóczay E, Fink N, et al. Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement. Circulation: Cardiovascular Imaging. 2024;17(10). doi:10.1161/circimaging.124.017112

BibTeX
@article{VecseyNagy2024,
  author = {Vecsey-Nagy, Milán and Tremamunno, Giuseppe and Schoepf, U Joseph and Gnasso, Chiara and Zsarnóczay, Emese and Fink, Nicola and Kravchenko, Dmitrij and Halfmann, Moritz C and Laux, Gerald S and O'Doherty, Jim and Szilveszter, Bálint and Maurovich-Horvat, Pál and Kabakus, Ismail Mikdat and Suranyi, Pal Spruill and Varga-Szemes, Akos and Emrich, Tilman},
  title = {Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement},
  journal = {Circulation: Cardiovascular Imaging},
  year = {2024},
  volume = {17},
  number = {10},
  doi = {10.1161/circimaging.124.017112}
}
Kostenlos starten →