EUVIMEDEUVIMED entdecken
Crossref

Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study

Mengzhen Wang, Xinrui Li, Zhihan Xu, Rui Chang, Wentao Han, Fuhua Yan, Mi Zhou, Wenjie Yang

American Journal of Roentgenology · 2025

DOI: 10.2214/ajr.25.33021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Roentgenology, 2025. Verfasst von Mengzhen Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Rd, Shanghai 200025, China. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Coronary Angiography, Coronary Stenosis. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND. The literature reports excellent diagnostic performance of coronary CTA using photon-counting detector (PCD) CT, albeit obtained using various acquisition and reconstruction protocols. OBJECTIVE. The purpose of this study was to assess the diagnostic performance for detecting significant stenosis of coronary CTA performed by PCD CT with various standard-resolution (SR) and ultrahigh-resolution (UHR) protocols, using invasive coronary angiography (ICA) as the reference standard. METHODS. This prospective study enrolled inpatients undergoing coronary CTA between October 2023 and October 2024. Participants underwent coronary CTA by PCD CT, sequentially alternating between SR (collimation: 144 × 0.4 mm) and UHR (collimation: 120 × 0.2 mm) modes across participants. SR examinations were reconstructed into normal (SRnormal) and virtual noncalcium (SRVNCa) image sets, both using 0.6-mm slice thickness and Bv40 kernel. UHR examinations were reconstructed into normal (UHRnormal [0.6-mm slice thickness, Bv40 kernel]) and thin (UHRthin [0.2-mm slice thickness, Bv64 kernel]) image sets. Two radiologists independently measured the diameter of stenoses. The final analysis included patients who underwent ICA after CTA; a cardiologist reviewed the ICA images to determine the reference standard. Stenoses were considered significant at a threshold of 50% or greater. RESULTS. The SR group included 61 patients (mean age, 67 ± 9 [SD] years; 46 men, 15 women; 788 segments analyzed). The UHR group included 61 patients (67 ± 11 years; 43 men, 18 women; 825 segments analyzed). Per-segment sensitivity, specificity, and accuracy for reader 1 were 92.9%, 89.9%, and 90.5% for SRnormal, respectively; 92.9%, 91.6%, and 91.8% for SRVNCa; 96.0%, 92.4%, and 93.0% for UHRnormal; and 100.0%, 98.6%, and 98.8% for UHRthin; and for reader 2 were 92.9%, 88.8%, and 89.6% for SRnormal; 93.5%, 92.3%, and 92.5% for SRVNCa; 96.0%, 91.6%, and 92.2% for UHRnormal; and 100.0%, 98.9%, and 99.0% for UHRthin. Significant (p < .05) differences included SRVNCa versus SRnormal for specificity for both readers and accuracy for reader 2; UHRthin versus UHRnormal for sensitivity, specificity, and accuracy for both readers; and UHRthin versus SRVNCa for sensitivity, specificity, and accuracy for both readers. CONCLUSION. Coronary CTA performed by PCD CT achieved high diagnostic performance in the SR or UHR mode. Performance was higher for SRVNCa than SRnormal and for UHRthin than either UHRnormal or SRVNCa. CLINICAL IMPACT. The findings will help to optimize protocols for coronary CTA performed by PCD CT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyCoronary AngiographyCoronary StenosisHumansProspective StudiesMaleFemaleMiddle AgedAgedPhotonsRadiographic Image Interpretation, Computer-AssistedSensitivity and Specificity

Stichwörter der Autor:innen

coronary CTAphoton-counting CTultrahigh-resolutionvirtual noncalcium algorithm

Autor:innen und Institutionen

  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Rd, Shanghai 200025, China.
  • Siemens Healthineers CT Collaboration, Shanghai, China.
  • Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Zitieren

APA

Wang, M., Li, X., Xu, Z., Chang, R., Han, W., Yan, F., Zhou, M., & Yang, W. (2025). Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study. American Journal of Roentgenology. https://doi.org/10.2214/ajr.25.33021

Vancouver

Wang M, Li X, Xu Z, Chang R, Han W, Yan F, et al. Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study. American Journal of Roentgenology. 2025. doi:10.2214/ajr.25.33021

BibTeX
@article{Wang2025,
  author = {Wang, Mengzhen and Li, Xinrui and Xu, Zhihan and Chang, Rui and Han, Wentao and Yan, Fuhua and Zhou, Mi and Yang, Wenjie},
  title = {Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study},
  journal = {American Journal of Roentgenology},
  year = {2025},
  doi = {10.2214/ajr.25.33021}
}
Kostenlos starten →