Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions – an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors
Clinical Oral Investigations · 2025
DOI: 10.1007/s00784-025-06400-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Oral Investigations, 2025. Verfasst von Juliana B Melo da Fonte und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Oral and Maxillofacial Diagnostic Sciences, School of Dental Medicine, University of Connecticut, Farmington, CT, USA. Hauptthemen laut MEDLINE: Dental Caries. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To compare the diagnostic performance of three intraoral complementary metal-oxide-semiconductor (CMOS) sensors, one based on direct conversion (CMOS-DC) and two scintillator-dependent sensors, in assessing noncavitated caries-like lesions. MATERIALS AND METHODS: Sixty extracted human caries-free teeth (30 premolars, 30 molars) were selected. A demineralizing solution was used to induce caries-like lesions on the distal surface of 15 premolars (dPM) and the mesial surface of 15 molars (dM), while the remaining teeth were kept sound (sPM, sM). Phantoms were mounted in 4 combinations: dPM-dM, dPM-sM, sPM-dM, and sPM-sM. Standardized radiographs were obtained with one CMOS-DC sensor (XpectVision XVD2530) and two conventional scintillator-dependent CMOS sensors (CMOS-C1: Dexis IXS, and CMOS-C2: Carestream RVG-6200). Three calibrated observers independently assessed the images using a 5-point scale. Observers' agreement, sensitivity, specificity, accuracy and area under the curve (AUC) were analyzed using Kappa, ANOVA, and Tukey test (p ≤ 0.05). RESULTS: Intra- and interobserver agreements ranged from fair to perfect. Specificity (70.57-83.35), accuracy (64.98-71.10), and AUC (72.63-78.00) showed no statistically significant differences (p > 0.05). The CMOS-DC sensor demonstrated significantly higher sensitivity than CMOS-C2 (p = 0.017). Across all sensors, sensitivity was greater for dPM, with higher AUC values for dPM on CMOS-C1 and CMOS-DC sensors. CONCLUSIONS: The novel CMOS-DC sensor performed comparably to the more commonly used sensors, with slightly superior sensitivity in diagnosing caries-like lesions when those were truly present. CLINICAL RELEVANCE: The novel CMOS sensor, based on direct conversion technology, has shown promise in enhancing diagnostic performance and improving clinical outcomes for noncavitated caries lesions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Oral and Maxillofacial Diagnostic Sciences, School of Dental Medicine, University of Connecticut, Farmington, CT, USA.
- College of Dentistry, University of Saskatchewan, 107 Wiggins Road, E3332 HSc, Saskatoon, SK, S7N5E5 , Canada. dani.pita@usask.ca.
- Department of Biomaterial and Biomedical Sciences, School of Dentistry, Oregon Health & Science University, Portland, OR, USA.
- Division of Oral Diagnostic Sciences, School of Dentistry, Oregon Health & Science University, Portland, OR, USA.
Zitieren
APA
da Fonte, J. B. M., Pita de Melo, D., Fugolin, A. P. P., & Sousa Melo, S. L. (2025). Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions – an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors. Clinical Oral Investigations. https://doi.org/10.1007/s00784-025-06400-7
Vancouver
da Fonte JBM, Pita de Melo D, Fugolin APP, Sousa Melo SL. Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions – an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors. Clinical Oral Investigations. 2025. doi:10.1007/s00784-025-06400-7
BibTeX
@article{daFonte2025,
author = {da Fonte, Juliana B Melo and Pita de Melo, Daniela and Fugolin, Ana Paula Piovezan and Sousa Melo, Saulo L},
title = {Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions – an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors},