Validity and Reliability of Intraoral OCT and Bitewing Radiography for Detecting Approximal Carious Lesions
Caries Research · 2025
DOI: 10.1159/000544789 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Caries Research, 2025. Verfasst von Michaela Strumpski und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cariology, Endodontology and Periodontology, University of Leipzig, Leipzig, Germany, michaela.strumpski@medizin.uni-leipzig.de. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Dental Caries, Radiography, Bitewing, Radiography, Dental, Digital. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
This in vitro study evaluated the validity and reliability of spectral domain optical coherence tomography (SD-OCT) to detect approximal carious lesions compared to bitewing radiography.
Methods
Forty extracted human premolars and molars with fifty-four unrestored approximal surfaces (ICDAS ll score 0 – 3) were mounted in a patient-equivalent simulator and imaged by digital radiography (DR) and the prototype of an intraoral OCT probe. The lesion status of the tooth surfaces was validated histologically and by microtomography (µCT). Five calibrated raters with low to high level of clinical expertise analyzed the DR and OCT images at intervals of 2 to 4 weeks each. Intra- and interrater agreement (weighted Cohen's kappa κ, Fleiss' kappa), sensitivity, and specificity were calculated.
Results
The sensitivity of OCT (0.66 - 0.91) was higher than that of DR (0.46 - 0.82), as was the specificity (OCT: 0.67 - 0.92; DR: 0.33 - 0.58). Intra-rater agreement with OCT was moderate to substantial (κ: 0.53 - 0.77; p < 0.001) and fair to substantial for DR (κ: 0.36 - 0.78; p < 0.05). The DR interpersonal agreement ranged from slight to substantial (κ: 0.1 - 0.74, Fleiss’-κ: 0.23/0.24; p < 0.001), towards fair to substantial with OCT (κ: 0.27 - 0.62; Fleiss’κ: 0.23/0.18; p < 0.001). Agreement between histology and µCT was almost perfect (κ: 0.82; p < 0.001).
Conclusions
In a clinically oriented simulation, OCT was more sensitive in detecting early approximal carious lesions than DR without impairing specificity or reproducibility. Clinical studies will have to show whether OCT can confirm these promising results. Clinical significance: Non-invasive real-time OCT imaging of the approximal spaces may validly and reproducibly supplement established diagnostic procedures for detecting and monitoring early approximal lesions. Training of examiners might further improve the interpretation of OCT images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cariology, Endodontology and Periodontology, University of Leipzig, Leipzig, Germany, michaela.strumpski@medizin.uni-leipzig.de.
- Department of Cariology, Endodontology and Periodontology, University of Leipzig, Leipzig, Germany.
Zitieren
APA
Strumpski, M., Schneider, H., Rüger, C., Schmidt, J., Schulz-Kornas, E., & Haak, R. (2025). Validity and Reliability of Intraoral OCT and Bitewing Radiography for Detecting Approximal Carious Lesions. Caries Research. https://doi.org/10.1159/000544789
Vancouver
Strumpski M, Schneider H, Rüger C, Schmidt J, Schulz-Kornas E, Haak R. Validity and Reliability of Intraoral OCT and Bitewing Radiography for Detecting Approximal Carious Lesions. Caries Research. 2025. doi:10.1159/000544789
BibTeX
@article{Strumpski2025,
author = {Strumpski, Michaela and Schneider, Hartmut and Rüger, Claudia and Schmidt, Jana and Schulz-Kornas, Ellen and Haak, Rainer},
title = {Validity and Reliability of Intraoral OCT and Bitewing Radiography for Detecting Approximal Carious Lesions},
journal = {Caries Research},
year = {2025},
doi = {10.1159/000544789}
}
EUVIMED