Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2026. Verfasst von Luca De Berardinis und 4 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic and Trauma Unit, IRCCS Ospedale San Raffaele, Milan, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Comparisons of cemented and cementless TKA have focused on mean outcomes and generally reported equivalence. We hypothesized that a 3D-printed full-titanium cementless TKA and the same-design cemented implant would not differ significantly in average joint awareness but would differ in the proportion of patients with the poorest results, and we compared the two both at the mean and across the outcome distribution.

Methods

Prospective two-cohort study of 109 primary unilateral TKAs (54 cementless, 55 cemented) for end-stage knee osteoarthritis, with complete 24-month follow-up. Exclusion criteria were valgus deformity and bilateral surgery. The primary outcome was the FJS-12, analysed both at the mean (multivariable linear regression, with propensity score overlap weighting as sensitivity analysis) and across its distribution (quantile regression). Secondary outcomes were PASS achievement (FJS-12 ≥ 33.3), OKS, and time to functional satisfaction.

Results

The cementless group was younger ( P < 0.001) with more men ( P = 0.008). Mean FJS-12 was not different between groups after adjustment (β = 7.4, 95% CI − 1.8 to 16.6, P = 0.115), although the confidence interval did not exclude a difference exceeding the minimal clinically important difference; this finding was reproduced by overlap weighting. On quantile regression, cementless patients scored significantly higher at the 10th and 25th percentiles (adjusted P = 0.028 and 0.021) but not at the median or above. A greater proportion of cementless patients achieved the PASS (96.3% vs. 76.4%; absolute difference 19.9%, 95% CI 7.1 to 32.9; number needed to treat 5), which persisted after adjustment ( P = 0.005). No significant differences were observed in OKS ( P = 0.91) or time to functional satisfaction (adjusted P = 0.39). No revisions or loosening occurred.

Conclusion

The 3D-printed full-titanium cementless TKA did not produce a significantly higher mean FJS-12 than the same-design cemented device at 24 months, but it significantly reduced the proportion of patients with poor joint awareness outcomes. Level of evidence III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeHumansMaleProspective StudiesProsthesis DesignAgedFemaleBone CementsPatient SatisfactionMiddle AgedPrinting, Three-Dimensional

Stichwörter der Autor:innen

3D printingCementedCementlessFull-titaniumTotal knee arthroplasty

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Orthopaedic and Trauma Unit, IRCCS Ospedale San Raffaele, Milan, Italy.
  • Institute of Biomechanics, Paracelsus Medical University (PMU), Salzburg, Austria.
  • University of Florence, Florence, Italy. filippo.leggieri@unifi.it.
  • Orthopaedic Unit, Istituto Fiorentino di Cura e Assistenza, Firenze, Italy.
  • Orthopaedic Unit, Istituto Clinico San Rocco di Ome, Brescia, Italy.

ORCID-Profile: Andrea Baldini

Zitieren

APA

De Berardinis, L., Leggieri, F., Salari, P., Polizzotti, G., & Baldini, A. (2026). Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-026-06531-w

Vancouver

De Berardinis L, Leggieri F, Salari P, Polizzotti G, Baldini A. Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant. Archives of Orthopaedic and Trauma Surgery. 2026. doi:10.1007/s00402-026-06531-w

BibTeX
@article{DeBerardinis2026,
  author = {De Berardinis, Luca and Leggieri, Filippo and Salari, Paolo and Polizzotti, Giuseppe and Baldini, Andrea},
  title = {Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  doi = {10.1007/s00402-026-06531-w}
}
Kostenlos starten →