Impact of femoral component flexion on gap balancing in varus knees using robotic technology: a comparative study of single-radius and multi-radius designs
Journal of Robotic Surgery · 2025
DOI: 10.1007/s11701-025-02752-0 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Robotic Surgery, 2025. Verfasst von Ratnakar Vecham und 6 weiteren Autor:innen. Beteiligte Einrichtung: Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Arthroplasty, Replacement, Knee, Prosthesis Design, Femur. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Accurate flexion-extension gap balancing is critical in total knee arthroplasty (TKA), influencing postoperative stability and longevity. Femoral component flexion in the sagittal plane has been suggested as a means to adjust gap balance; however, its impact across different implant designs remains unclear. This study compares the influence of femoral component flexion on gap balancing between single-radius and multi-radius femoral components using robotic-assisted TKA. A prospective observational cohort study was conducted on 200 patients (100 in each cohort) undergoing primary robotic-assisted TKA for varus deformity with end-stage osteoarthritis. Patients were randomized to receive either single-radius (Stryker MAKO with Stryker Triathlon implants) or multi-radius (Meril CUVIS with Maxx-Freedom implants) femoral components. Intraoperative medial and lateral flexion-extension gaps were assessed at femoral flexion increments from 0° to 6° using robotic measurement software, and statistical analyses were done. Femoral component flexion had distinct impacts on gap balancing depending on implant design. Multi-radius implants showed significant variability with extension medial gaps progressively loosened (mean Change 0.19 mm/degree of flexion, p 0.05). Femoral component flexion significantly affects gap balancing during robotic-assisted TKA, particularly in multi-radius femoral components. Multi-radius designs require careful sagittal alignment to prevent undesirable gap variations, whereas single-radius implants exhibit more predictable gap balancing profiles, potentially simplifying intraoperative adjustments. Future research should evaluate long-term clinical outcomes related to these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India.
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India. tarunjaykumar@gmail.com.
Zitieren
APA
Vecham, R., Madhavan, P., Jayakumar, T., Karumuri, K., Mulpur, P., Annapareddy, A., & Reddy, A. V. G. (2025). Impact of femoral component flexion on gap balancing in varus knees using robotic technology: a comparative study of single-radius and multi-radius designs. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-025-02752-0
Vancouver
Vecham R, Madhavan P, Jayakumar T, Karumuri K, Mulpur P, Annapareddy A, et al. Impact of femoral component flexion on gap balancing in varus knees using robotic technology: a comparative study of single-radius and multi-radius designs. Journal of Robotic Surgery. 2025. doi:10.1007/s11701-025-02752-0
BibTeX
@article{Vecham2025,
author = {Vecham, Ratnakar and Madhavan, Paramanantham and Jayakumar, Tarun and Karumuri, Kishore and Mulpur, Praharsha and Annapareddy, Adarsh and Reddy, A V Gurava},
title = {Impact of femoral component flexion on gap balancing in varus knees using robotic technology: a comparative study of single-radius and multi-radius designs},
journal = {Journal of Robotic Surgery},
year = {2025},
doi = {10.1007/s11701-025-02752-0}
}
EUVIMED