EUVIMEDEUVIMED entdecken
VergleichsstudieKontrollierte klinische Studie

No clinical relevant differences in early clinical outcomes, patient satisfaction and objective gait and posture analysis between a custom versus off-the-shelf total knee arthroplasty: a prospective controlled study

Alexander Zeh, Julia Stier, Lucas Meyer, David Wohlrab, Natalia Gutteck, Stephan Schulze, Matti Panian, Stefan Delank, Kevin Laudner, Rene Schwesig

Archives of Orthopaedic and Trauma Surgery · 2025

DOI: 10.1007/s00402-025-05854-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Alexander Zeh und 9 weiteren Autor:innen. Beteiligte Einrichtung: Martin Luther University Halle-Wittenberg, Halle, Germany. alexander.zeh@uk-halle.de. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Gait, Patient Satisfaction, Osteoarthritis, Knee. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 88 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Osteoarthritis is one of the most frequent joint diseases in the world. Therefore, it is critical to develop sufficient therapy strategies to improve a patient's quality of life. The aim of this study was to evaluate the influence of an individualized (custTKA) vs. a conventional (convTKA) total knee arthroplasty (TKA) in regard to gait, posture and clinical outcome. Seventy-three patients (male: n = 32, female: n = 41; age: 66.5 ± 8.64 years; BMI: 32.2 ± 5.68 kg/m2; axis pre-operative: 174 ± 4.65°) were included in this prospective controlled trial study (examinations 1, 2 and 3: preoperative, 3 and 12 months postoperative). Two experienced senior surgeons performed the surgeries. Clinical results were measured using the Forgotten Knee Joint Score (FKJS) and Knee Society Score (KSS). Additionally, gait was measured with inertial sensor based mobile and treadmill based systems, while posture was measured with a posturographic system in order to assess gait patterns and postural stability, regulation and weight distribution. Radiographic evaluation was measured of the hip knee ankle (HKA)) at 3 and 12 months postoperative. There were no clinically significant interaction effects (time x group) for posture (e.g., stability indicator, postural subsystems) or gait (e.g., stride length, walking speed, double support). However, time effects were observed for the somatosensory system (p = 0.005, ηp2 = 0.08), medio-lateral weight distribution (p < 0.001, ηp2 = 0.31), stride length (p < 0.001, ηp2 = 0.21), walking speed (p < 0.001, ηp2 = 0.21), cadence (p < 0.001, ηp2 = 0.18), stance phase (p < 0.001, ηp2 = 0.20) and maximum toe force (p < 0.001, ηp2 = 0.24). No significant differences were found for KSS or FJS 3 and 12 months postoperative (custTKA/convTKA: KSS examination 2 179/189, p = 0.153; KSS examination 3 206/198, p = 0.246; FKJS examination 2 41.4/40.7, p = 0.900; FKJS examination 3 54.9/45.8, p = 0.149). Similarly, no significant differences were noted for flexion at 3 (113/119°, p = 0.062) and 12 months postoperative (121/122°, p = 0.615). Radiographic diagnostic (HKA) also displayed no significant-relevant interaction effects. In this prospective controlled study no clinical significant-relevant interaction effects (group x time) were found between both techniques regarding biomechanical and clinical parameters. Therefore, it can be concluded that custTKA provides no substantial clinical benefits compared to convTKA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeGaitPatient SatisfactionOsteoarthritis, KneePostureKnee ProsthesisHumansMaleFemaleAgedProspective StudiesMiddle AgedTreatment OutcomeProsthesis Design

Stichwörter der Autor:innen

CustomGait analysisPatient-individualizedPosturographyTKA

Autor:innen und Institutionen

  • Martin Luther University Halle-Wittenberg, Halle, Germany. alexander.zeh@uk-halle.de.
  • Martin Luther University Halle-Wittenberg, Halle, Germany.
  • BG Klinikum Bergmannstrost Halle, Halle, Germany.
  • University of Colorado, Department of Health Sciences, Hybl Sports Medicine and Performance Center, Colorado Springs, USA.

Zitieren

APA

Zeh, A., Stier, J., Meyer, L., Wohlrab, D., Gutteck, N., Schulze, S., Panian, M., Delank, S., Laudner, K., & Schwesig, R. (2025). No clinical relevant differences in early clinical outcomes, patient satisfaction and objective gait and posture analysis between a custom versus off-the-shelf total knee arthroplasty: a prospective controlled study. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-05854-4

Vancouver

Zeh A, Stier J, Meyer L, Wohlrab D, Gutteck N, Schulze S, et al. No clinical relevant differences in early clinical outcomes, patient satisfaction and objective gait and posture analysis between a custom versus off-the-shelf total knee arthroplasty: a prospective controlled study. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-05854-4

BibTeX
@article{Zeh2025,
  author = {Zeh, Alexander and Stier, Julia and Meyer, Lucas and Wohlrab, David and Gutteck, Natalia and Schulze, Stephan and Panian, Matti and Delank, Stefan and Laudner, Kevin and Schwesig, Rene},
  title = {No clinical relevant differences in early clinical outcomes, patient satisfaction and objective gait and posture analysis between a custom versus off-the-shelf total knee arthroplasty: a prospective controlled study},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2025},
  doi = {10.1007/s00402-025-05854-4}
}
Kostenlos starten →