Efficacy of 1 mSv ultra-low-dose CT with automated volume analyzer software for detecting residual tiny fragments and dust particles after laser lithotripsy: an ex vivo Phantom study
World Journal of Urology · 2026
DOI: 10.1007/s00345-026-06281-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Urology, 2026. Verfasst von Naoto Tanaka und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Hara Genitourinary Hospital, Kobe, Hyogo, 650-0012, Japan. naoto.t501@gmail.com. Hauptthemen laut MEDLINE: Lithotripsy, Laser, Tomography, X-Ray Computed, Kidney Calculi, Dust. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: Radiation exposure remains a major concern for patients with urolithiasis who undergo frequent imaging for diagnosis, treatment, and follow-up. The dusting technique generates numerous small-sized fragments and dust particles, some of which remain in the kidney as residual stones. Although ultra-low-dose computed tomography (ULDCT) has demonstrated comparable performance to standard-dose computed tomography (SDCT) for detecting urinary stones above a certain size, its utility in detecting very small stones ( 0.05) and for differentiating dust from larger fragments, whereas significant differences in these characteristics were observed among the stone categories (p < 0.001). CONCLUSION: In this ex vivo study, ULDCT provided quantitative CT characteristics comparable to those obtained with SDCT for very small stones, including dust. These findings support its potential utility for postoperative assessment after laser lithotripsy, although clinical in vivo validation is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Urology, Hara Genitourinary Hospital, Kobe, Hyogo, 650-0012, Japan. naoto.t501@gmail.com.
- Department of Urology, National Academy of Medical Sciences, Bir Hospital, Mahaboudha, Kathmandu, Bagmati, Nepal.
- Division of Urology, Department of Surgery Related, Kobe University Graduate School of Medicine, Kobe, Hyogo, 650-0017, Japan.
- Department of Urology, Hara Genitourinary Hospital, Kobe, Hyogo, 650-0012, Japan.
Zitieren
APA
Tanaka, N., Chitrakar, A., Kitamura, S., Katsura, D., Yamamichi, F., Kaku, Y., Fukiishi, Y., Fujita, M., & Inoue, T. (2026). Efficacy of 1 mSv ultra-low-dose CT with automated volume analyzer software for detecting residual tiny fragments and dust particles after laser lithotripsy: an ex vivo Phantom study. World Journal of Urology. https://doi.org/10.1007/s00345-026-06281-9
Vancouver
Tanaka N, Chitrakar A, Kitamura S, Katsura D, Yamamichi F, Kaku Y, et al. Efficacy of 1 mSv ultra-low-dose CT with automated volume analyzer software for detecting residual tiny fragments and dust particles after laser lithotripsy: an ex vivo Phantom study. World Journal of Urology. 2026. doi:10.1007/s00345-026-06281-9