Pushing the limits of cardiac MRI: deep-learning based real-time cine imaging in free breathing vs breath hold

Ann-Christin Klemenz, Lena-Maria Watzke, Karolin K Deyerberg, Benjamin Böttcher, Margarita Gorodezky, Mathias Manzke, Antonia Dalmer, Roberto Lorbeer, Marc-André Weber, Felix G Meinel

European Radiology · 2025

DOI: 10.1007/s00330-025-11941-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, 2025. Verfasst von Ann-Christin Klemenz und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany. Hauptthemen laut MEDLINE: Breath Holding, Magnetic Resonance Imaging, Cine, Deep Learning, Heart. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate deep-learning (DL) based real-time cardiac cine sequences acquired in free breathing (FB) vs breath hold (BH). Materials and methods In this prospective single-centre cohort study, 56 healthy adult volunteers were investigated on a 1.5-T MRI scanner. A set of real-time cine sequences, including a short-axis stack, 2-, 3-, and 4-chamber views, was acquired in FB and with BH. A validated DL-based cine sequence acquired over three cardiac cycles served as the reference standard for volumetric results. Subjective image quality (sIQ) was rated by two blinded readers. Volumetric analysis of both ventricles was performed. Results sIQ was rated as good to excellent for FB real-time cine images, slightly inferior to BH real-time cine images ( p < 0.0001). Overall acquisition time for one set of cine sequences was 50% shorter with FB (median 90 vs 180 s, p < 0.0001). There were significant differences between the real-time sequences and the reference in left ventricular (LV) end-diastolic volume, LV end-systolic volume, LV stroke volume and LV mass. Nevertheless, BH cine imaging showed excellent correlation with the reference standard, with an intra-class correlation coefficient (ICC) > 0.90 for all parameters except right ventricular ejection fraction (RV EF, ICC = 0.887). With FB cine imaging, correlation with the reference standard was good for LV ejection fraction (LV EF, ICC = 0.825) and RV EF (ICC = 0.824) and excellent (ICC > 0.90) for all other parameters.

Conclusion

DL-based real-time cine imaging is feasible even in FB with good to excellent image quality and acceptable volumetric results in healthy volunteers. Key Points Question Conventional cardiac MR (CMR) cine imaging is challenged by arrhythmias and patients unable to hold their breath, since data is acquired over several heartbeats .

Findings

DL-based real-time cine imaging is feasible in FB with acceptable volumetric results and reduced acquisition time by 50% compared to real-time breath-hold sequences . Clinical relevance This study fits into the wider goal of increasing the availability of CMR by reducing the complexity, duration of the examination and improving patient comfort and making CMR available even for patients who are unable to hold their breath . Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breath HoldingMagnetic Resonance Imaging, CineDeep LearningHeartHumansMaleFemaleAdultProspective StudiesMiddle AgedImage Interpretation, Computer-AssistedRespiration

Stichwörter der Autor:innen

Accelerated imagingCardiac MRClinical imagingDeep learningFree breathing

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
  • GE HealthCare, Munich, Germany.
  • Department of Radiology, Ludwig-Maximilians University, Munich, Germany.
  • Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany. felix.meinel@med.uni-rostock.de.

Zitieren

APA

Klemenz, A. C., Watzke, L. M., Deyerberg, K. K., Böttcher, B., Gorodezky, M., Manzke, M., Dalmer, A., Lorbeer, R., Weber, M. A., & Meinel, F. G. (2025). Pushing the limits of cardiac MRI: deep-learning based real-time cine imaging in free breathing vs breath hold. European Radiology. https://doi.org/10.1007/s00330-025-11941-2

Vancouver

Klemenz AC, Watzke LM, Deyerberg KK, Böttcher B, Gorodezky M, Manzke M, et al. Pushing the limits of cardiac MRI: deep-learning based real-time cine imaging in free breathing vs breath hold. European Radiology. 2025. doi:10.1007/s00330-025-11941-2

BibTeX
@article{Klemenz2025,
  author = {Klemenz, Ann-Christin and Watzke, Lena-Maria and Deyerberg, Karolin K and Böttcher, Benjamin and Gorodezky, Margarita and Manzke, Mathias and Dalmer, Antonia and Lorbeer, Roberto and Weber, Marc-André and Meinel, Felix G},
  title = {Pushing the limits of cardiac MRI: deep-learning based real-time cine imaging in free breathing vs breath hold},
  journal = {European Radiology},
  year = {2025},
  doi = {10.1007/s00330-025-11941-2}
}
Kostenlos starten →