EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Accelerated Cine Cardiac MRI Using Deep Learning‐Based Reconstruction: A Systematic Evaluation

Amol Pednekar iD, Murat Kocaoglu, Hui Wang, Aki Tanimoto, Jean A Tkach iD, Sean Lang iD, Michael D Taylor

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29081 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Amol Pednekar und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Deep Learning, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Breath‐holding (BH) for cine balanced steady state free precession (bSSFP) imaging is challenging for patients with impaired BH capacity. Deep learning‐based reconstruction (DLR) of undersampled k‐space promises to shorten BHs while preserving image quality and accuracy of ventricular assessment.

Purpose

To perform a systematic evaluation of DLR of cine bSSFP images from undersampled k‐space over a range of acceleration factors. Study Type Retrospective. Subjects Fifteen pectus excavatum patients (mean age 16.8 ± 5.4 years, 20% female) with normal cardiac anatomy and function and 12‐second BH capability. Field Strength/Sequence 1.5‐T, cine bSSFP. Assessment Retrospective DLR was conducted by applying compressed sensitivity encoding (C‐SENSE) acceleration to systematically undersample fully sampled k‐space cine bSSFP acquisition data over an acceleration/undersampling factor ( R ) considering a range of 2 to 8. Quality imperceptibility (QI) measures, including structural similarity index measure, were calculated using images reconstructed from fully sampled k‐space as a reference. Image quality, including contrast and edge definition, was evaluated for diagnostic adequacy by three readers with varying levels of experience in cardiac MRI (>4 years, >18 years, and 1 year). Automated DL‐based biventricular segmentation was performed commercially available software by cardiac radiologists with more than 4 years of experience. Statistical Tests Tukey box plots, linear mixed effects model, analysis of variance (ANOVA), weighted kappa, Kruskal–Wallis test, and Wilcoxon signed‐rank test were employed as appropriate. A P ‐value

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance Imaging, CineDeep LearningImage Processing, Computer-AssistedHumansFemaleMaleRetrospective StudiesAdolescentYoung AdultHeartBreath HoldingChildImage Interpretation, Computer-AssistedReproducibility of ResultsAdult

Stichwörter der Autor:innen

adaptive intelligencebiventricular volumecardiac MRIcine imagingcompressed SENSE

Autor:innen und Institutionen

  • Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.
  • MR Clinical Science, Philips Healthcare, Cincinnati, Ohio, USA.
  • The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.

ORCID-Profile: Amol Pednekar, Jean A Tkach, Sean Lang

Zitieren

APA

Pednekar, A., Kocaoglu, M., Wang, H., Tanimoto, A., Tkach, J. A., Lang, S., & Taylor, M. D. (2024). Accelerated Cine Cardiac MRI Using Deep Learning‐Based Reconstruction: A Systematic Evaluation. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29081

Vancouver

Pednekar A, Kocaoglu M, Wang H, Tanimoto A, Tkach JA, Lang S, et al. Accelerated Cine Cardiac MRI Using Deep Learning‐Based Reconstruction: A Systematic Evaluation. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29081

BibTeX
@article{Pednekar2024,
  author = {Pednekar, Amol and Kocaoglu, Murat and Wang, Hui and Tanimoto, Aki and Tkach, Jean A and Lang, Sean and Taylor, Michael D},
  title = {Accelerated Cine Cardiac MRI Using Deep Learning‐Based Reconstruction: A Systematic Evaluation},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29081}
}
Kostenlos starten →