Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Xianghu Yan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Heart Ventricles, Deep Learning. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Youth Fund of Hubei Science and Technology Plan, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Conventional segmented, retrospectively gated cine (Conv‐cine) is challenged in patients with breath‐hold difficulties. Compressed sensing (CS) has shown values in cine imaging but generally requires long reconstruction time. Recent artificial intelligence (AI) has demonstrated potential in fast cine imaging.

Purpose

To compare CS‐cine and AI‐cine with Conv‐cine in quantitative biventricular functions, image quality, and reconstruction time. Study Type Prospective human studies. Subjects 70 patients (age, 39 ± 15 years, 54.3% male). Field Strength/Sequence 3T; balanced steady state free precession gradient echo sequences. Assessment Biventricular functional parameters of CS‐, AI‐, and Conv‐cine were measured by two radiologists independently and compared. The scan and reconstruction time were recorded. Subjective scores of image quality were compared by three radiologists. Statistical Tests Paired t ‐test and two related‐samples Wilcoxon sign test were used to compare biventricular functional parameters between CS‐, AI‐, and Conv‐cine. Intraclass correlation coefficient (ICC), Bland–Altman analysis, and Kendall's W method were applied to evaluate agreement of biventricular functional parameters and image quality of these three sequences. A P ‐value 0.05), except for very small differences in left ventricle end‐diastole volumes of 2.5 mL (SMD = 0.082) and 4.1 mL (SMD = 0.096), respectively. Bland–Altman scatter plots revealed that biventricular function results were mostly distributed within the 95% confidence interval. All parameters had acceptable to excellent interobserver agreements (ICC: 0.748–0.989). Compared with Conv‐cine (84 ± 13 sec), both CS (14 ± 2 sec) and AI (15 ± 2 sec) techniques reduced scan time. Compared with CS‐cine (304 ± 17 sec), AI‐cine (24 ± 4 sec) reduced reconstruction time. CS‐cine demonstrated significantly lower quality scores than Conv‐cine, while AI‐cine demonstrated similar scores ( P = 0.634).

Conclusion

CS‐ and AI‐cine can achieve whole‐heart cardiac cine imaging in a single breath‐hold. Both CS‐ and AI‐cine have the potential to supplement the gold standard Conv‐cine in studying biventricular functions and benefit patients having difficulties with breath‐holds. Level of Evidence 1 Technical Efficacy Stage 1

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart VentriclesDeep LearningHumansMaleYoung AdultAdultMiddle AgedFemaleRetrospective StudiesArtificial IntelligenceProspective StudiesImage Interpretation, Computer-AssistedBreath HoldingMagnetic Resonance Imaging, CineReproducibility of Results

Stichwörter der Autor:innen

artificial intelligencebiventriclecompressed sensingdeep learningfunction

Autor:innen und Institutionen

  • Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • United Imaging Intelligence, Cambridge, Massachusetts, USA.
  • UIH America, Inc., Houston, Texas, USA.
  • Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen, Guangdong, China.
  • Department of Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

ORCID-Profile: Xianghu Yan, Lixian Zou, Liming Xia

Förderung

  • Youth Fund of Hubei Science and Technology Plan
  • National Natural Science Foundation of China

Zitieren

APA

Yan, X., Luo, Y., Chen, X., Chen, E. Z., Liu, Q., Zou, L., Bao, Y., Huang, L., & Xia, L. (2024). From Compressed‐Sensing to Deep Learning MR : Comparative Biventricular Cardiac Function Analysis in a Patient Cohort. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.28899

Vancouver

Yan X, Luo Y, Chen X, Chen EZ, Liu Q, Zou L, et al. From Compressed‐Sensing to Deep Learning MR : Comparative Biventricular Cardiac Function Analysis in a Patient Cohort. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.28899

BibTeX
@article{Yan2024,
  author = {Yan, Xianghu and Luo, Yi and Chen, Xiao and Chen, Eric Z and Liu, Qi and Zou, Lixian and Bao, Yuwei and Huang, Lu and Xia, Liming},
  title = {From Compressed‐Sensing to Deep Learning MR : Comparative Biventricular Cardiac Function Analysis in a Patient Cohort},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.28899}
}
Kostenlos starten →