Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial
Abdominal Radiology · 2024
DOI: 10.1007/s00261-024-04637-6 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Abdominal Radiology, 2024. Verfasst von Yoshifumi Noda und 9 weiteren Autor:innen. Beteiligte Einrichtung: Massachusetts General Hospital, Boston, USA. noda.yoshifumi.g9@f.gifu-u.ac.jp. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Dual-Energy Scanned Projection, Radiographic Image Interpretation, Computer-Assisted, Pancreatic Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the impact of optimized trigger threshold on 40-keV pancreatic phase images acquired with a dual-energy CT (DECT) protocol. METHODS: A cohort of 69 consecutive participants (median age, 72 years) undergoing a pancreatic protocol DECT examination between September to December 2021 were prospectively randomized into two protocols: conventional trigger threshold of 100 HU (Group A, n = 34) and optimized trigger threshold of 30 HU (Group B, n = 35). Pancreatic phase image acquisition was performed with fixed delay of 20 s from the trigger threshold. Two radiologists assessed the 40-keV pancreatic phase images for scan timing adequacy using a binary scale (adequate or inadequate). The proportions of these classifications were compared in the two groups using the Fisher's test. RESULTS: The median times to achieve the aortic attenuation of 30 HU and 100 HU were 16.3 s and 22.3 s in Group A, respectively, and was 17.8 s for 30 HU in Group B. The median time difference from 30 HU to 100 HU was 4.5 s in Group A. The scan timing adequacies of pancreatic phase images were classified as adequate (50.0% and 74.3%) or inadequate (50.0% and 25.7%) in Group A and Group B (P = 0.049). CONCLUSION: An optimized trigger threshold of 30 HU allows consistent acquisition of adequate pancreatic phase images compared to the conventional trigger threshold of 100 HU for pancreatic protocol DECT at 40-keV which might lead to improved pancreatic lesion conspicuity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Massachusetts General Hospital, Boston, USA. noda.yoshifumi.g9@f.gifu-u.ac.jp.
- Gifu University, Gifu City, Japan. noda.yoshifumi.g9@f.gifu-u.ac.jp.
- Gifu University, Gifu City, Japan.
- Massachusetts General Hospital, Boston, USA.
Zitieren
APA
Noda, Y., Koyasu, H., Kambadakone, A., Kawai, N., Naruse, T., Ito, A., Kaga, T., Hyodo, F., Kato, H., & Matsuo, M. (2024). Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial. Abdominal Radiology. https://doi.org/10.1007/s00261-024-04637-6
Vancouver
Noda Y, Koyasu H, Kambadakone A, Kawai N, Naruse T, Ito A, et al. Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial. Abdominal Radiology. 2024. doi:10.1007/s00261-024-04637-6
BibTeX
@article{Noda2024,
author = {Noda, Yoshifumi and Koyasu, Hiromi and Kambadakone, Avinash and Kawai, Nobuyuki and Naruse, Takuya and Ito, Akio and Kaga, Tetsuro and Hyodo, Fuminori and Kato, Hiroki and Matsuo, Masayuki},
title = {Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial},
journal = {Abdominal Radiology},
year = {2024},
doi = {10.1007/s00261-024-04637-6}
}
EUVIMED