Diagnostic accuracy of Dual-Energy CT in detecting traumatic vertebral bone marrow edema: a prospective comparative study with MRI in the context of a level I trauma center
Neuroradiology · 2025
DOI: 10.1007/s00234-025-03763-2 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Neuroradiology, 2025. Verfasst von Thomas Beyer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, Paediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany. t…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Edema, Tomography, X-Ray Computed, Bone Marrow Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: GE HealthCare.
Abstract (Originalsprache)
Background
Traumatic vertebral fractures present a significant diagnostic challenge in emergency settings. Magnetic resonance imaging (MRI) excels in detecting bone marrow edema but faces practical limitations in acute trauma care. This prospective study evaluates the diagnostic accuracy of Dual-Energy Computed Tomography (DECT) in detecting traumatic vertebral bone marrow edema within a Level I trauma center environment.
Methods
Between May 2020 and July 2023, 291 DECT examinations were performed on adult patients presenting with suspected or confirmed spinal injury. From these, 233 (80.1%) met quality criteria for analysis. A subgroup of 47 patients underwent additional MRI as reference standard, with 44 (93.6%) providing diagnostically evaluable images. Two board-certified radiologists independently assessed vertebral bone marrow edema presence in blinded, randomized evaluations using both modalities. Diagnostic parameters, examination times, radiation exposure, and cost-efficiency were analyzed.
Results
DECT demonstrated an overall sensitivity of 82.9% and specificity of 96.6% for detecting vertebral bone marrow edema compared to MRI. The thoracolumbar junction showed highest sensitivity (91.7% for L3). DECT examination time was 7.2 minutes (including post-processing) versus 12 minutes for MRI, meaning MRI required 66.7% more time than DECT. DECT radiation exposure showed a mean dose-length product increase of only 3% compared to conventional CT. Body mass index showed no significant influence on DECT interpretability (p=0.196) or diagnostic accuracy except in isolated segments (L3, T11). Cost-benefit analysis revealed potential savings of 49.1% (€104.40) per spinal segment with DECT-based diagnostic pathways.
Conclusion
DECT offers high diagnostic accuracy for detecting traumatic vertebral bone marrow edema with substantial time and cost advantages compared to MRI. The technique demonstrates particular value in acute trauma settings, while acknowledging limitations from artifacts (19.9% of cases) primarily caused by medical devices. These findings support implementing DECT as an efficient alternative to MRI in spinal trauma diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Diagnostic and Interventional Radiology, Paediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany. thomas.beyer@med.uni-rostock.de.
- Institute of Diagnostic and Interventional Radiology, Paediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
- Department of Trauma, Hand and Reconstructive Surgery, Rostock University Medical Center, Rostock, Germany.
- Institute of Diagnostic and Interventional Radiology, Paediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany. marc-andre.weber@med.uni-rostock.de.
Förderung
- GE HealthCare
Zitieren
APA
Beyer, T., Volmer, E., Gahr, P., & Weber, M. A. (2025). Diagnostic accuracy of Dual-Energy CT in detecting traumatic vertebral bone marrow edema: a prospective comparative study with MRI in the context of a level I trauma center. Neuroradiology. https://doi.org/10.1007/s00234-025-03763-2
Vancouver
Beyer T, Volmer E, Gahr P, Weber MA. Diagnostic accuracy of Dual-Energy CT in detecting traumatic vertebral bone marrow edema: a prospective comparative study with MRI in the context of a level I trauma center. Neuroradiology. 2025. doi:10.1007/s00234-025-03763-2
BibTeX
@article{Beyer2025,
author = {Beyer, Thomas and Volmer, Erik and Gahr, Patrick and Weber, Marc-André},
title = {Diagnostic accuracy of Dual-Energy CT in detecting traumatic vertebral bone marrow edema: a prospective comparative study with MRI in the context of a level I trauma center},
journal = {Neuroradiology},
year = {2025},
doi = {10.1007/s00234-025-03763-2}
}