Comparison of the different imaging time points in delayed dual-energy CT extracellular volume in assessing the staging of liver fibrosis
British Journal of Radiology · 2025
DOI: 10.1093/bjr/tqaf177 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Chuanlin Yu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hunan Provincial People's Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, Hunan 410005, Chi…. Hauptthemen laut MEDLINE: Liver Cirrhosis, Tomography, X-Ray Computed, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
Objective
To stage liver fibrosis by using delayed dual-energy CT (DECT) and determine the optimal delay time for acquisition of delayed CT scans. Materials and methods This prospective study included patients with chronic liver disease, who were scheduled to undergo multiphase abdominal DECT (including 3-min and 5-min delayed periods) and liver biopsies from January 2021 to December 2021. The iodine densities of the parenchyma and aorta were measured and extracellular volume (ECV) was calculated. Kendall rank correlation was employed to assess the relationship between the ECV and the fibrosis stage. Comparison of ECVs was made for different stages of liver fibrosis. In addition, the diagnostic performances of ECV for staging liver fibrosis were evaluated by using receiver operating characteristic (ROC) curve analysis, and area under the curve (AUC) was calculated.
Results
A total of 90 participants were evaluated, and distributed as follows: 10 in S1, 29 in S2, 25 in S3, and 26 in S4. Both ECV of 3-min delayed (ECV3 min) and 5-min delayed (ECV5 min) showed a positive correlation with the stage of liver fibrosis (ECV3 min: τ = 0.478, P < .01, moderate correlation; ECV5 min: τ = 0.352, P < .01, weak correlation). In terms of diagnostic performances, ECV3 min showed significantly higher diagnostic accuracy than ECV5 min for significant liver fibrosis (S2–4) (AUC: 0.87 vs 0.79, P = .037), but no significant differences were observed for progressive fibrosis (S3–4) (AUC: 0.76 vs 0.71, P = .206) or cirrhosis (S4) (AUC: 0.75 vs 0.74, P = .774).
Conclusions
DECT ECV may have some potential in noninvasively liver fibrosis staging, ECV3 min is not definitely inferior to ECV5 min. Advances in knowledge A 3-min delay for the delayed-phase ECV assessment can guide clinical treatment decisions for patients and enhance the efficiency of scanning work, holding significant clinical value.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Hunan Provincial People's Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, Hunan 410005, China.
- Department of PET-CT Center, Hunan Cancer Hospital (The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University), Changsha, Hunan 410005, China.
ORCID-Profile: Peng Liu, Yaqiong He
Zitieren
APA
Yu, C., Zhou, W., Peng, Y., Dai, T., Liu, P., & He, Y. (2025). Comparison of the different imaging time points in delayed dual-energy CT extracellular volume in assessing the staging of liver fibrosis. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf177
Vancouver
Yu C, Zhou W, Peng Y, Dai T, Liu P, He Y. Comparison of the different imaging time points in delayed dual-energy CT extracellular volume in assessing the staging of liver fibrosis. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf177
BibTeX
@article{Yu2025,
author = {Yu, Chuanlin and Zhou, Wanjing and Peng, Yingjie and Dai, Ting and Liu, Peng and He, Yaqiong},
title = {Comparison of the different imaging time points in delayed dual-energy CT extracellular volume in assessing the staging of liver fibrosis},
journal = {British Journal of Radiology},
year = {2025},
doi = {10.1093/bjr/tqaf177}
}
EUVIMED