EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT

Stephan Rau, Alexander Rau, Thomas Stein, Muhammad Taha Hagar, Sebastian Faby, Fabian Bamberg, Jakob Weiss

La radiologia medica · 21.03.2024 · 129 (5) · 669-676

DOI: 10.1007/s11547-024-01801-2 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift La radiologia medica, online erschienen am 21.03.2024. Verfasst von Stephan Rau und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freibu…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Kidney Diseases, Cystic. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerium für Wirtschaft, Arbeit und Wohnungsbau Baden-Württemberg, Siemens Healthineers, Universitätsklinikum Freiburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the value of photon-counting detector CT (PCD-CT) derived virtual non-contrast (VNC) reconstructions to identify renal cysts in comparison with conventional dual-energy integrating detector (DE EID) CT-derived VNC reconstructions. Material and methods We prospectively enrolled consecutive patients with simple renal cysts (Bosniak classification—Version 2019, density ≤ 20 HU and/or enhancement ≤ 20 HU) who underwent multiphase (non-contrast, arterial, portal venous phase) PCD-CT and for whom non-contrast and portal venous phase DE EID-CT was available. Subsequently, VNC reconstructions were calculated for all contrast phases and density as well as contrast enhancement within the cysts were measured and compared. MRI and/or ultrasound served as reference standards for lesion classification.

Results

19 patients (1 cyst per patient; age 69.5 ± 10.7 years; 17 [89.5%] male) were included. Density measurements on PCD-CT non-contrast and VNC reconstructions (arterial and portal venous phase) revealed no significant effect on HU values ( p = 0.301). In contrast, a significant difference between non-contrast vs. VNC images was found for DE EID-CT ( p = 0.02). For PCD-CT, enhancement for VNC reconstructions was < 20 HU for all evaluated cysts. DE EID-CT measurements revealed an enhancement of > 20 HU in five lesions (26.3%) using the VNC reconstructions, which was not seen with the non-contrast images.

Conclusion

PCD-CT-derived VNC images allow for reliable and accurate characterization of simple cystic renal lesions similar to non-contrast scans whereas VNC images calculated from DE EID-CT resulted in substantial false characterization. Thus, PCD-CT-derived VNC images may substitute for non-contrast images and reduce radiation dose and follow-up imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedKidney Diseases, CysticHumansMaleFemaleAgedProspective StudiesMiddle AgedPhotonsAged, 80 and overRadiography, Dual-Energy Scanned Projection

Stichwörter der Autor:innen

Photon-Counting CTRenal lesionsTomographyVirtual non-contrastX-Ray Computed

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany. stephan.rau@uniklinik-freiburg.de.
  • Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
  • Siemens Healthcare GmbH, Siemensstr. 3, 91301, Forchheim, Germany.

Förderung

  • Ministerium für Wirtschaft, Arbeit und Wohnungsbau Baden-Württemberg
  • Siemens Healthineers
  • Universitätsklinikum Freiburg

Zitieren

APA

Rau, S., Rau, A., Stein, T., Hagar, M. T., Faby, S., Bamberg, F., & Weiss, J. (2024). Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT. La radiologia medica, 129(5), 669-676. https://doi.org/10.1007/s11547-024-01801-2

Vancouver

Rau S, Rau A, Stein T, Hagar MT, Faby S, Bamberg F, et al. Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT. La radiologia medica. 2024;129(5):669-676. doi:10.1007/s11547-024-01801-2

BibTeX
@article{Rau2024,
  author = {Rau, Stephan and Rau, Alexander and Stein, Thomas and Hagar, Muhammad Taha and Faby, Sebastian and Bamberg, Fabian and Weiss, Jakob},
  title = {Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT},
  journal = {La radiologia medica},
  year = {2024},
  volume = {129},
  number = {5},
  pages = {669--676},
  doi = {10.1007/s11547-024-01801-2}
}
Kostenlos starten →