Protocol optimization for abdominal imaging using photon-counting CT: a consensus of two academic institutions
Abdominal Radiology · 2024
DOI: 10.1007/s00261-024-04254-3 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Abdominal Radiology, 2024. Verfasst von Fides R Schwartz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Duke University Hospital and Brigham and Women's Hospital, Boston, USA. frschwartz@bwh.harvard.edu. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Abdominal, Radiation Dosage. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Photon-counting detector CT (PCD CT) is a promising technology for abdominal imaging due to its ability to provide high spatial and contrast resolution images with reduced patient radiation exposure. However, there is currently no consensus regarding the optimal imaging protocols for PCD CT. This article aims to present the PCD CT abdominal imaging protocols used by two tertiary care academic centers in the United States. METHODS: A review of PCD CT abdominal imaging protocols was conducted by two abdominal radiologists at different academic institutions. Protocols were compared in terms of acquisition parameters and reconstruction settings. Both imaging centers independently selected similar protocols for PCD CT abdominal imaging, using QuantumPlus mode. RESULTS: There were some differences in the use of reconstruction kernels and iterative reconstruction levels, however the individual combination at each site resulted in similar image impressions. Overall, the imaging protocols used by both centers provide high-quality images with low radiation exposure. CONCLUSION: These findings provide valuable insights into the development of standardized protocols for PCD CT abdominal imaging, which can help to ensure consistent as well as high-quality imaging across different institutions and allow for future multicenter research collaborations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Duke University Hospital and Brigham and Women's Hospital, Boston, USA. frschwartz@bwh.harvard.edu.
- Duke University Hospital, Durham, USA.
- Siemens Healthineers, Malvern, PA, USA.
- New York University Langone Hospital, New York, USA.
Zitieren
APA
Schwartz, F. R., Marin, D., Lofino, L., Abadia, A., O'Donnell, T., & Dane, B. (2024). Protocol optimization for abdominal imaging using photon-counting CT: a consensus of two academic institutions. Abdominal Radiology. https://doi.org/10.1007/s00261-024-04254-3
Vancouver
Schwartz FR, Marin D, Lofino L, Abadia A, O'Donnell T, Dane B. Protocol optimization for abdominal imaging using photon-counting CT: a consensus of two academic institutions. Abdominal Radiology. 2024. doi:10.1007/s00261-024-04254-3
BibTeX
@article{Schwartz2024,
author = {Schwartz, Fides R and Marin, Daniele and Lofino, Ludovica and Abadia, Andres and O'Donnell, Thomas and Dane, Bari},
title = {Protocol optimization for abdominal imaging using photon-counting CT: a consensus of two academic institutions},
journal = {Abdominal Radiology},
year = {2024},
doi = {10.1007/s00261-024-04254-3}
}
EUVIMED