Evaluation of multi-keV PureCalcium images from photon-counting CT for abdominal imaging: A comparison with true and conventional virtual non-contrast images
European Journal of Radiology · 2026
DOI: 10.1016/j.ejrad.2025.112640 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Liming Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe East Road, Erqi District, Zhengzhou, Henan 450000, China…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Abdominal, Radiographic Image Interpretation, Computer-Assisted, Calcium. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Henan Provincial Science and Technology Research Project.
Abstract (Originalsprache)
PURPOSE: To determine which keV PureCa images can effectively substitute TNC images for abdominal imaging. METHODS: A total of 50 consecutive patients who underwent thoracoabdominal scans on Photon-Counting CT from January to April 2025 were included. A true non-contrast (TNC), arterial (CTA) and venous (CTV) phase images were analyzed. Conventional virtual non-contrast (VNC) and 5 PureCa images were reconstructed from each contrast phase. Attenuation values and noise on 12 regions of interest were measured. Overall image quality, contrast removal and calcium preservation were analyzed using a 5-point scale. The paired t-tests and Friedman tests were applied to compare objective and subjective results. RESULTS: 70 keV yielded the smallest HUerror in the majority of abdominal tissues during the arterial and venous phase. The overall trend demonstrated a plateau in noise reduction beyond 65 keV. Compared with VNC images, PureCa demonstrated significantly lower HUerror in key soft tissues: Liver: 2 (1-6) HU vs 5 (3-8) HU (P = 0.001), Muscle: 2 (1-4) HU vs 10 (7-14) HU (P < 0.001), subcutaneous adipose tissue: 2.5 (1-4) HU vs 39 (33-42) HU (P < 0.001). All patients had a subjective score of 3 or above. 65-70 keV PureCa images were rated significantly higher than 50-60 keV images, and comparable to VNC, but still inferior to TNC (P < 0.05). CONCLUSIONS: PureCa images reconstructed at 70 keV on photon-counting CT systems provide accurate attenuation values and satisfactory image quality for abdominal tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe East Road, Erqi District, Zhengzhou, Henan 450000, China; Henan Key Laboratory of Image Diagnosis and Treatment for Digestive…
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe East Road, Erqi District, Zhengzhou, Henan 450000, China.
- CT Collaboration, Siemens Healthineers, 399 West Haiyang Road, Shanghai 200126, China.
Förderung
- Henan Provincial Science and Technology Research Project
Zitieren
APA
Li, L., Yao, Y., Nie, K., Yuan, M., Fan, S., & Gao, J. (2026). Evaluation of multi-keV PureCalcium images from photon-counting CT for abdominal imaging: A comparison with true and conventional virtual non-contrast images. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112640
Vancouver
Li L, Yao Y, Nie K, Yuan M, Fan S, Gao J. Evaluation of multi-keV PureCalcium images from photon-counting CT for abdominal imaging: A comparison with true and conventional virtual non-contrast images. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2025.112640
BibTeX
@article{Li2026,
author = {Li, Liming and Yao, Yang and Nie, Kehui and Yuan, Mengchen and Fan, Songmei and Gao, Jianbo},
title = {Evaluation of multi-keV PureCalcium images from photon-counting CT for abdominal imaging: A comparison with true and conventional virtual non-contrast images},
journal = {European Journal of Radiology},
year = {2026},
doi = {10.1016/j.ejrad.2025.112640}
}
EUVIMED