Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence
Skeletal Radiology · 2023
DOI: 10.1007/s00256-023-04325-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skeletal Radiology, 2023. Verfasst von Andrea Ferrero und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, 55902, MN, USA. Hauptthemen laut MEDLINE: Femoracetabular Impingement. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: The feasibility of low-dose photon-counting detector (PCD) CT to measure alpha and acetabular version angles of femoroacetabular impingement (FAI). MATERIAL AND METHODS: FAI patients undergoing an energy-integrating detector (EID) CT underwent an IRB-approved prospective ultra-high-resolution (UHR) PCD-CT between 5/2021 and 12/2021. PCD-CT was dose-matched to the EID-CT or acquired at 50% dose. Simulated 50% dose EID-CT images were generated. Two radiologists evaluated randomized EID-CT and PCD-CT images and measured alpha and acetabular version angles on axial image slices. Image quality (noise, artifacts, and visualization of cortex) and confidence in non-FAI pathology were rated on a 4-point scale (3 = adequate). Preference tests of standard dose PCD-CT, 50% dose PCD-CT, and 50% dose EID-CT relative to standard dose EID-CT were performed using Wilcoxon Rank test. RESULTS: 20 patients underwent standard dose EID-CT (~ CTDIvol, 4.5 mGy); 10 patients, standard dose PCD-CT (4.0 mGy); 10 patients, 50% PCD-CT (2.6 mGy). Standard dose EID-CT images were scored as adequate for diagnostic task in all categories (range 2.8-3.0). Standard dose PCD-CT images scored higher than the reference in all categories (range 3.5-4, p < 0.0033). Half-dose PCD-CT images also scored higher for noise and cortex visualization (p < 0.0033) and equivalent for artifacts and visualization of non-FAI pathology. Finally, simulated 50% EID-CT images scored lower in all categories (range 1.8-2.4, p < 0.0033). CONCLUSIONS: Dose-matched PCD-CT is superior to EID-CT for alpha angle and acetabular version measurement in the work up of FAI. UHR-PCD-CT enables 50% radiation dose reduction compared to EID while remaining adequate for the imaging task.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, 55902, MN, USA.
- Department of Orthopedic Surgery and Sports Medicine, Mayo Clinic, Rochester, MN, USA.
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, 55902, MN, USA. Baffour.Francis@mayo.edu.
Zitieren
APA
Ferrero, A., Powell, G. M., Adaaquah, D. K., Rajendran, K., Thorne, J. E., Krych, A. J., Horst, K. K., McCollough, C. H., & Baffour, F. I. (2023). Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence. Skeletal Radiology. https://doi.org/10.1007/s00256-023-04325-4
Vancouver
Ferrero A, Powell GM, Adaaquah DK, Rajendran K, Thorne JE, Krych AJ, et al. Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence. Skeletal Radiology. 2023. doi:10.1007/s00256-023-04325-4
BibTeX
@article{Ferrero2023,
author = {Ferrero, Andrea and Powell, Garret M and Adaaquah, Dennis K and Rajendran, Kishore and Thorne, Jamison E and Krych, Aaron J and Horst, Kelly K and McCollough, Cynthia H and Baffour, Francis I},
title = {Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence},
journal = {Skeletal Radiology},
year = {2023},
doi = {10.1007/s00256-023-04325-4}
}
EUVIMED