Simultaneous Bilateral T 1 , T 2 , and T 1ρ Relaxation Mapping of Hip Joint With 3D ‐ MRI Fingerprinting
Journal of Magnetic Resonance Imaging · 2025
DOI: 10.1002/jmri.29679 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Anmol Monga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional, Hip Joint, Osteoarthritis, Hip. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIAMS NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Background
Three‐dimensional MR fingerprinting (3D‐MRF) has been increasingly used to assess cartilage degeneration, particularly in the knee joint, by looking into multiple relaxation parameters. A comparable 3D‐MRF approach can be adapted to assess cartilage degeneration for the hip joint, with changes to accommodate specific challenges of hip joint imaging.
Purpose
To demonstrate the feasibility and repeatability of 3D‐MRF in the bilateral hip jointly we map proton density (PD), T 1 , T 2 , T 1ρ , and ∆ B 1+ in clinically feasible scan times. Study Type Prospective. Subjects Eight healthy subjects, three patients with mild osteoarthritis (OA), and one of the OA patients had femoral acetabular impingement (FAI). A National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine (NIST/ISMRM) system phantom was also used. Field Strength/Sequence 3 T, 3D‐MRF sequence for bilateral hip joint mapping. Reference sequences include Volume Interpolated Breath‐hold Examination (VIBE) for T 1 mapping, and magnetization‐prepared fast low‐angle shot (TFL) for T 2 and T 1ρ mapping. Assessment The signal‐to‐noise ratio (SNR), repeatability, scan time, and accuracy of T 1 , T 2 , and T 1ρ maps of 3D‐MRF sequence were evaluated on a NIST/ISMRM phantom and human subjects. Differences in the parametric maps between OA and healthy subjects were assessed. Statistical Tests Regression, Bland–Altman, Kruskal–Wallis, and Wilcoxon tests were used to assess for accuracy, repeatability, and subregional variation. The P ‐value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
- Department of Orthopedic Surgery, New York University Grossman School of Medicine, New York, New York, USA.
- Department of Medicine, Division of Rheumatology, New York University Grossman School of Medicine, New York, New York, USA.
ORCID-Profile: Anmol Monga, Hector Lise de Moura, Marcelo V W Zibetti, Ravinder R Regatte
Förderung
- NIH HHS
- NIAMS NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Monga, A., de Moura, H. L., Zibetti, M. V. W., Youm, T., Samuels, J., & Regatte, R. R. (2025). Simultaneous Bilateral T 1 , T 2 , and T 1ρ Relaxation Mapping of Hip Joint With 3D ‐ MRI Fingerprinting. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29679
Vancouver
Monga A, de Moura HL, Zibetti MVW, Youm T, Samuels J, Regatte RR. Simultaneous Bilateral T 1 , T 2 , and T 1ρ Relaxation Mapping of Hip Joint With 3D ‐ MRI Fingerprinting. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29679