EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative radiation dose analysis in pediatric high-pitch cardiac CTA using photon-counting versus energy-integrating detector CT

Gladys M Arguello Fletes, Wei Zhou, LaDonna J Malone, Andrea I Fuentealba Cargill, Jason P Weinman, Lorna P Browne

Pediatric Radiology · 2025

DOI: 10.1007/s00247-025-06336-w ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Pediatric Radiology, 2025. Verfasst von Gladys M Arguello Fletes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Colorado School of Medicine/Department of Pediatric Radiology, Children's Hospital Colorado, 13123 East 16th A…. Hauptthemen laut MEDLINE: Radiation Dosage, Computed Tomography Angiography, Heart Defects, Congenital, Coronary Angiography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Previous studies have shown improved image quality in pediatric cardiac imaging using photon-counting detector CT (PCDCT). However, these studies did not evaluate image quality and radiation dose when utilizing the full spectral capabilities of PCDCT scanners. The full spectral capability of PCDCT scanners allows the generation of the entire array of mono-energetic reconstructions, virtual non-contrast (VNC) images, and iodine maps, which have potential advantages in evaluating complex congenital heart disease. For example, following complex congenital cardiac repairs, when distinguishing intraluminal or soft tissue calcifications from contrast, or when evaluating intrastent thrombus. OBJECTIVE: To compare image quality and radiation dose between high-pitch cardiac CT using full spectral PCDCT and dual-source energy-integrating detector CT (EIDCT). MATERIALS AND METHODS: This retrospective, IRB-approved study analyzed high-pitch cardiac CTs from January 2021 to October 2023 in pediatric patients ( 12 months. In the EIDCT, 80/100 (80%) (P = 0.05) were ≤ 12 months, and 20/100 (20%) (P = 0.05) were > 12 months. In patients ≤ 12 months, the CNR were 31.61 in the PCDCT group and 32.14 in the EIDCT group (P = 0.39). For those > 12 months, CNR were 30.07 for PCDCT and 25.27 for EIDCT (P = 0.17). In patients ≤ 12 months, SNR was significantly lower (P 12 months, SNR was not significantly lower (P = 0.89); SNR was similar between scanners. Radiation doses were significantly higher for PCDCT across both age groups (P < 0.0001). CONCLUSION: High-pitch cardiac CT with PCDCT using spectral processing resulted in higher radiation doses and lower SNR in infants compared to EIDCT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageComputed Tomography AngiographyHeart Defects, CongenitalCoronary AngiographyHumansChildRetrospective StudiesMaleFemaleChild, PreschoolInfantAdolescentPhotonsRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Dual-source energy-Iintegrating detector CTHigh-Pitch cardiac CTPhoton-counting detector CT

Autor:innen und Institutionen

  • Department of Radiology, University of Colorado School of Medicine/Department of Pediatric Radiology, Children's Hospital Colorado, 13123 East 16th Avenue, Box 125, Aurora, 80045, Colorado, USA. gladys.arguellofletes@ch…
  • School of Medicine, University of Colorado, Aurora, USA. gladys.arguellofletes@childrenscolorado.org.
  • Department of Radiology, University of Colorado School of Medicine/Department of Pediatric Radiology, Children's Hospital Colorado, 13123 East 16th Avenue, Box 125, Aurora, 80045, Colorado, USA.
  • School of Medicine, University of Colorado, Aurora, USA.

Zitieren

APA

Arguello Fletes, G. M., Zhou, W., Malone, L. J., Fuentealba Cargill, A. I., Weinman, J. P., & Browne, L. P. (2025). Comparative radiation dose analysis in pediatric high-pitch cardiac CTA using photon-counting versus energy-integrating detector CT. Pediatric Radiology. https://doi.org/10.1007/s00247-025-06336-w

Vancouver

Arguello Fletes GM, Zhou W, Malone LJ, Fuentealba Cargill AI, Weinman JP, Browne LP. Comparative radiation dose analysis in pediatric high-pitch cardiac CTA using photon-counting versus energy-integrating detector CT. Pediatric Radiology. 2025. doi:10.1007/s00247-025-06336-w

BibTeX
@article{ArguelloFletes2025,
  author = {Arguello Fletes, Gladys M and Zhou, Wei and Malone, LaDonna J and Fuentealba Cargill, Andrea I and Weinman, Jason P and Browne, Lorna P},
  title = {Comparative radiation dose analysis in pediatric high-pitch cardiac CTA using photon-counting versus energy-integrating detector CT},
  journal = {Pediatric Radiology},
  year = {2025},
  doi = {10.1007/s00247-025-06336-w}
}
Kostenlos starten →