EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Expansion of Typical Values for Paediatric Patients in Ireland and Comparison with Published DRLs - Experiences of a Single Institution

Andrew Lyons, Ali Mohammed Ali, Andrew England, Niamh Moore, Rena Young, Brid Leamy, Winnie Tam, Paul Bezzina, Napapong Pongnapang, Mark F McEntee

Journal of Medical Imaging and Radiation Sciences · 2024

DOI: 10.1016/j.jmir.2024.04.014 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Medical Imaging and Radiation Sciences, 2024. Verfasst von Andrew Lyons und 9 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland. Hauptthemen laut MEDLINE: Radiation Dosage. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: To reduce the risks involved with ionising radiation exposure, typical values (TVs) and diagnostic reference levels (DRLs) have been established to help keep radiation doses 'as low as reasonably practicable. TVs/DRLs provide standardised radiation dose metrics that can be used for comparative purposes. However, for paediatrics, such values should consider the size of the child instead of their age. This study aimed to establish and compare paediatric TVs for chest, abdomen and pelvis radiography. METHODS: Study methods followed processes for establishing paediatric DRLs as outlined by the Health Information and Quality Authority (HIQA). Kerma-area product (KAP) values, excluding rejected images, were retrospectively acquired from the study institution's Picture Archiving and Communications System (PACS). Paediatric patients were categorised into the following weight-based groupings (5 to

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageHumansChildIrelandChild, PreschoolInfantMaleFemaleInfant, NewbornAdolescentReference ValuesRadiography, ThoracicRetrospective StudiesDiagnostic Reference LevelsRadiographyRadiation Protection

Stichwörter der Autor:innen

ALARADiagnostic reference levelsDose area productPaediatricRadiation protection

Autor:innen und Institutionen

  • Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland.
  • Department of Medical Physics, College of Applied Medical Sciences, University of Kerbala, Karbala, Iraq.
  • Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland. Electronic address: aengland@ucc.ie.
  • Department of Radiology, Cork University Hospital, Cork, Ireland.
  • Department of Radiography, City, University of London, London, UK.
  • Department of Radiography, University of Malta, Msida, Malta.

Zitieren

APA

Lyons, A., Mohammed Ali, A., England, A., Moore, N., Young, R., Leamy, B., Tam, W., Bezzina, P., Pongnapang, N., & McEntee, M. F. (2024). Expansion of Typical Values for Paediatric Patients in Ireland and Comparison with Published DRLs - Experiences of a Single Institution. Journal of Medical Imaging and Radiation Sciences. https://doi.org/10.1016/j.jmir.2024.04.014

Vancouver

Lyons A, Mohammed Ali A, England A, Moore N, Young R, Leamy B, et al. Expansion of Typical Values for Paediatric Patients in Ireland and Comparison with Published DRLs - Experiences of a Single Institution. Journal of Medical Imaging and Radiation Sciences. 2024. doi:10.1016/j.jmir.2024.04.014

BibTeX
@article{Lyons2024,
  author = {Lyons, Andrew and Mohammed Ali, Ali and England, Andrew and Moore, Niamh and Young, Rena and Leamy, Brid and Tam, Winnie and Bezzina, Paul and Pongnapang, Napapong and McEntee, Mark F},
  title = {Expansion of Typical Values for Paediatric Patients in Ireland and Comparison with Published DRLs - Experiences of a Single Institution},
  journal = {Journal of Medical Imaging and Radiation Sciences},
  year = {2024},
  doi = {10.1016/j.jmir.2024.04.014}
}
Kostenlos starten →