Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes

Takanori Masuda iD, Masao Kiguchi iD, Chikako Fujioka iD, Takayuki Oku iD, Toru Ishibashi iD, Yasushi Katsunuma iD, Takayasu Yoshitake iD, Shuji Abe iD, Kazuo Awai iD

Pediatric Radiology · 2024

DOI: 10.1007/s00247-024-05947-z ↗

At a glance

Vergleichsstudie in Pediatric Radiology, 2024. Written by Takanori Masuda and 8 co-authors. Institution: Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, …. Major MEDLINE topics: Lens, Crystalline, Scattering, Radiation, Tomography, X-Ray Computed, Radiation Dosage. Cited 5 times so far (Crossref); 32 references. Funded by: Academic Research Grant from the Japanese Society of Radiological Technology.

AbstractSubjectsBibliografiska uppgifterCiteRelated studies

Abstract (original language)

BACKGROUND: Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce. OBJECTIVE: To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations. MATERIALS AND METHODS: Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.625-mm multidetector; and Aquilion ONE GENESIS Edition (Canon Medical Systems, Otawara, Japan) with a 320-row, 0.5-mm multidetector. Three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The scatter dose values measured by the OSLDs were compared between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width during pediatric chest CT examinations. RESULTS: Median equivalent doses for the helical and axial scans were 0.12 and 0.12 mSv/mGy for the newborn, 0.17 and 0.16 mSv/mGy for the 1-year-old, and 0.18 and 0.15 mSv/mGy for the 5-year-old, respectively, when using the Revolution CT. With the Revolution CT, no significant differences were observed in the scatter doses between helical and axial scans in the newborn and 1-year-old phantoms. However, the lens scatter dose for the helical scan was approximately 20-35% higher than that for the axial scan in the 5-year-old phantom (P

Subjects

MeSH terms (MEDLINE)

Lens, CrystallineScattering, RadiationTomography, X-Ray ComputedRadiation DosageHumansMaleFemaleTomography, Spiral ComputedPhantoms, ImagingRadiometryRadiation ExposureInfant, NewbornInfantChild, Preschool

Author keywords

Computed tomographyLensPediatricsScatter dose

Authors and institutions

  • Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Okayama, Japan. takanorimasuda@yahoo.co.jp.
  • Department of Radiology, Hiroshima University, Hiroshima, Japan.
  • Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan.
  • Department of Radiological Technology, Tokai University Oiso Hospital, Kanagawa, Japan.
  • Towcar Works Co., Ltd, Oita, Japan.
  • Department of Radiological Technology, Osaka College of High Technology, Osaka, Japan.

ORCID profiles: Takanori Masuda, Masao Kiguchi, Chikako Fujioka, Takayuki Oku, Toru Ishibashi, Yasushi Katsunuma, Takayasu Yoshitake, Shuji Abe, Kazuo Awai

Funding

  • Academic Research Grant from the Japanese Society of Radiological Technology

Cite

APA

Masuda, T., Kiguchi, M., Fujioka, C., Oku, T., Ishibashi, T., Katsunuma, Y., Yoshitake, T., Abe, S., & Awai, K. (2024). Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes. Pediatric Radiology. https://doi.org/10.1007/s00247-024-05947-z

Vancouver

Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, et al. Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes. Pediatric Radiology. 2024. doi:10.1007/s00247-024-05947-z

BibTeX
@article{Masuda2024,
  author = {Masuda, Takanori and Kiguchi, Masao and Fujioka, Chikako and Oku, Takayuki and Ishibashi, Toru and Katsunuma, Yasushi and Yoshitake, Takayasu and Abe, Shuji and Awai, Kazuo},
  title = {Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes},
  journal = {Pediatric Radiology},
  year = {2024},
  doi = {10.1007/s00247-024-05947-z}
}
Start for free →