Comparison of the equivalent doses of the eye lenses, thyroid, and mammary gland among three pediatric and one adult anthropomorphic phantom during the chest CT examinations using a 40 mm volume helical scan
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae165 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Takanori Masuda und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, …. Hauptthemen laut MEDLINE: Phantoms, Imaging, Thyroid Gland, Lens, Crystalline, Radiation Dosage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
Equivalent doses for the eye lenses, thyroid, and mammary glands were measured and compared between one adult and three pediatric anthropomorphic phantoms during chest computed tomography (CT) using 40 mm volume helical scan on the Aquilion ONE GENESIS Edition CT equipment. Placing an optically stimulated luminescence dosemeter (OSLD) on the eye lenses, thyroid, and mammary gland, we measured and compared the equivalent dose of OSLD among different phantoms during chest CT using a helical scan. Compared with adults, the equivalent doses to the eye lens, thyroid, and mammary glands were ~81%, 77%, and 63% lower in newborns, 1-year-olds, and 5-year-olds using comparable image noise during chest CT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan.
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan.
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
- Department of Radiological Technology, Tokai University Oiso Hospital, 143, Iseharashi, Naka-gun, Kanagawa 259-1193, Japan.
- TOWCAR WORKS Co., Ltd, Kusu-cho233-, Kusugun, Ooita 879-4403, Japan.
- Department of Radiological Technology, Osaka College of High Technology, Osaka, Japan.
ORCID-Profile: Takanori Masuda, Takayuki Oku, Toru Ishibashi
Zitieren
APA
Masuda, T., Kiguchi, M., Fujioka, C., Oku, T., Ishibashi, T., Katsunuma, Y., Yoshitake, T., Abe, S., & Awai, K. (2024). Comparison of the equivalent doses of the eye lenses, thyroid, and mammary gland among three pediatric and one adult anthropomorphic phantom during the chest CT examinations using a 40 mm volume helical scan. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae165
Vancouver
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, et al. Comparison of the equivalent doses of the eye lenses, thyroid, and mammary gland among three pediatric and one adult anthropomorphic phantom during the chest CT examinations using a 40 mm volume helical scan. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae165
BibTeX
@article{Masuda2024,
author = {Masuda, Takanori and Kiguchi, Masao and Fujioka, Chikako and Oku, Takayuki and Ishibashi, Toru and Katsunuma, Yasushi and Yoshitake, Takayasu and Abe, Shuji and Awai, Kazuo},
title = {Comparison of the equivalent doses of the eye lenses, thyroid, and mammary gland among three pediatric and one adult anthropomorphic phantom during the chest CT examinations using a 40 mm volume helical scan},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae165}
}
EUVIMED