EUVIMEDEUVIMED entdecken
Crossref

Quantitative single photon emission tomography: verification for sources in an elliptical water phantom

M H Ljungberg, M A King, S E Strand

European Journal of Nuclear Medicine · 1992

DOI: 10.1007/bf00168157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine, 1992. Verfasst von M H Ljungberg und 2 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Physics Department, University of Lund, Sweden. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Tomography, Emission-Computed, Single-Photon. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate absorbed dose calculations are important for a proper dose planning in internal radionuclide therapy. The activity distribution must be measured and the target volume defined. This can be done with single photon emission tomography (SPET) if proper attenuation and scatter correction are employed. This study investigated the calculation of the activity and the volume of different spherical sources. These two parameters are essential for a proper dose calculation. The scatter and attenuation correction method is based on spatially variant scatter functions and density maps. The volume calculation method is based on obtaining a threshold from a grey-level histogram. Both point sources and spheres of different diameters containing technetium-99m were placed in different locations in an elliptical water phantom and imaged by SPET. The activity and the volume of the spheres were calculated from the SPET images and compared with known activities. Results show a quantification of activity within 10% for most of the sources. Important influences on the quantification are (a) the presence of artefacts due to improper reconstruction and (b) the finite spatial resolution which affects the total number of counts within the determined volume.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedTomography, Emission-Computed, Single-PhotonHumansModels, StructuralMonte Carlo MethodRadioimmunotherapyRadiometryRadiotherapy DosageScattering, RadiationWater

Substanzen

Water

Autor:innen und Institutionen

  • Radiation Physics Department, University of Lund, Sweden.

Förderung

  • NCI NIH HHS

Zitieren

APA

Ljungberg, M. H., King, M. A., & Strand, S. E. (1992). Quantitative single photon emission tomography: verification for sources in an elliptical water phantom. European Journal of Nuclear Medicine. https://doi.org/10.1007/bf00168157

Vancouver

Ljungberg MH, King MA, Strand SE. Quantitative single photon emission tomography: verification for sources in an elliptical water phantom. European Journal of Nuclear Medicine. 1992. doi:10.1007/bf00168157

BibTeX
@article{Ljungberg1992,
  author = {Ljungberg, M H and King, M A and Strand, S E},
  title = {Quantitative single photon emission tomography: verification for sources in an elliptical water phantom},
  journal = {European Journal of Nuclear Medicine},
  year = {1992},
  doi = {10.1007/bf00168157}
}
Kostenlos starten →