Impact of cone‐beam computed tomography artifacts on dose calculation accuracy for lung cancer
Medical Physics · 2024
DOI: 10.1002/mp.16994 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Lukas Schröder und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Lung Neoplasms, Artifacts, Radiotherapy Dosage. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Background
To implement image‐guided adaptive radiotherapy (IGART), many studies investigated dose calculations on cone‐beam computed tomography (CBCT). A high HU accuracy is crucial for a high dose calculation accuracy and many imaging sites showed satisfactory results. It has been shown that the dose calculation accuracy for lung cancer lags behind.
Purpose
To examine why the dose calculation accuracy for lung is insufficient, the relative effects of the field‐of‐view (FOV), breathing motion, and scatter on dose calculation accuracy were studied.
Methods
A framework was built to simulate CBCT scans for lung cancer patients by forward projecting repeat CT (rCT) scans for two scan geometries: small (SFOV) and medium FOV (MFOV). Breathing motion was modeled by applying a 4D deformation vector field to the mid‐position rCT. Scatter was modeled by Monte‐Carlo simulations with/without an anti‐scatter grid (ASG). Simulated projections were reconstructed using filtered back‐projection with/without scatter correction. In case of the SFOV, the CBCT images were patched with the planning CT scan in axial direction. The treatment plan was recalculated on the rCT and simulated CBCT. The mean Hounsfield unit (HU) difference (ΔHU mean ), the structural similarity index measure (SSIM), and γ metrics were calculated for the CBCT datasets of various imaging settings.
Results
The differences in HU, SSIM and dose calculation accuracy for CBCTs with and without breathing motion were negligible (mean ΔHU mean = 6.4 vs. 13.7, mean SSIM = 0.941 vs. 0.957, mean γ (ref = MFOV) = 0.75). The SFOV resulted in a lower HU (mean ΔHU mean = −9.2 vs. 13.7) and SSIM (mean SSIM = 0.912 vs. 0.957), and therefore in dose differences compared to the MFOV (mean γ = 1.22). Scatter led to considerable discrepancies in all metrics. Adding only the ASG improved the results more than only applying a scatter correction algorithm. Combining ASG and scatter correction algorithm resulted in an even higher dose calculation accuracy.
Conclusions
Scatter and FOV are the main contributors to dose inaccuracies and motion has only a minor effect on dose calculation accuracy. Therefore, utilizing an appropriate scatter correction and FOV is important to achieve sufficient dose calculation accuracy to facilitate IGART for lung.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
- Techna Institute and Princess Margaret Cancer Centre, University Health Network, Toronto, Canada.
Zitieren
APA
Schröder, L., Bootsma, G., Stankovic, U., Ploeger, L., & Sonke, J. J. (2024). Impact of cone‐beam computed tomography artifacts on dose calculation accuracy for lung cancer. Medical Physics. https://doi.org/10.1002/mp.16994
Vancouver
Schröder L, Bootsma G, Stankovic U, Ploeger L, Sonke JJ. Impact of cone‐beam computed tomography artifacts on dose calculation accuracy for lung cancer. Medical Physics. 2024. doi:10.1002/mp.16994
BibTeX
@article{Schrder2024,
author = {Schröder, Lukas and Bootsma, Gregory and Stankovic, Uros and Ploeger, Lennert and Sonke, Jan-Jakob},
title = {Impact of cone‐beam computed tomography artifacts on dose calculation accuracy for lung cancer},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.16994}
}
EUVIMED