Comparing the intraocular pressure values obtained with a rebound tonometer (TONOVET Plus) and an indentation tonometer (IOPvet) in dogs with and without ocular disease
Veterinary Record · 15.06.2024 · 194 (12)
DOI: 10.1002/vetr.4269 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Record, online erschienen am 06.06.2024. Verfasst von Bertrand Michaud und 1 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Service, Clinique Vétérinaire AnimaVet, Saint Genis Pouilly, France. Hauptthemen laut MEDLINE: Tonometry, Ocular, Dog Diseases, Intraocular Pressure, Eye Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Background
This study aimed to compare the intraocular pressure (IOP) values obtained from two groups of dogs using the IOPvet indentation tonometer to those obtained from the same dogs using an established rebound tonometer (TONOVET Plus).
Methods
Tonometry was performed on 36 dogs with ocular diseases (70 eyes; group A) and 25 healthy dogs (49 eyes; group B). First, the TONOVET Plus rebound tonometer was used. Then, one drop of oxybuprocaine hydrochloride was applied to each eye, and 1 minute later, the IOP was estimated using the IOPvet.
Results
The IOPvet was safe, well tolerated and easy to use. The instrument had a high specificity (98.5%) for identifying IOPs of 20 mmHg or less. A lack of sensitivity (67.9%) was noted when evaluating eyes with an IOP between 20 and 30 mmHg. The sensitivity (33.3%) for identifying canine eyes with an IOP of greater than 30 mmHg ( n = 24) was low.
Limitations
This study lacks manometric work, which would be hard to justify with client‐owned dogs. Quantitative numerical data were compared with qualitative values and the same investigator obtained readings using both tonometers without being masked.
Conclusions
The IOPvet is highly sensitive for assessing normal IOPs, but underestimation of higher IOPs can lead to poor diagnostics. Digital tonometers remain the best way to assess IOP in veterinary clinics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Service, Clinique Vétérinaire AnimaVet, Saint Genis Pouilly, France.
- Genetic Department, University Hospital of Orléans, Orléans, France.
ORCID-Profile: Bertrand Michaud
Zitieren
APA
Michaud, B., & Lesne, F. (2024). Comparing the intraocular pressure values obtained with a rebound tonometer (TONOVET Plus) and an indentation tonometer (IOPvet) in dogs with and without ocular disease. Veterinary Record, 194(12). https://doi.org/10.1002/vetr.4269
Vancouver
Michaud B, Lesne F. Comparing the intraocular pressure values obtained with a rebound tonometer (TONOVET Plus) and an indentation tonometer (IOPvet) in dogs with and without ocular disease. Veterinary Record. 2024;194(12). doi:10.1002/vetr.4269
BibTeX
@article{Michaud2024,
author = {Michaud, Bertrand and Lesne, Fabien},
title = {Comparing the intraocular pressure values obtained with a rebound tonometer (TONOVET Plus) and an indentation tonometer (IOPvet) in dogs with and without ocular disease},
journal = {Veterinary Record},
year = {2024},
volume = {194},
number = {12},
doi = {10.1002/vetr.4269}
}