EUVIMEDObjevte EUVIMED
Systematische ÜbersichtMetaanalyseOpen access · CC BY-NC-ND 4.0

Test accuracy of rapid diagnostic tests and reverse‐transcription polymerase chain reaction against virus isolation in cell culture for assessing SARS‐CoV‐2 infectivity: Systematic review and meta‐analysis

Alexey Fomenko iD, Theo Dähne iD, Stephanie Weibel iD, Marcus Panning iD, Kathrin Grummich iD, Sabrina Schlesinger iD, Gerta Rücker iD, Hartmut Hengel iD

Reviews in Medical Virology · 2024

DOI: 10.1002/rmv.2569 ↗

At a glance

Systematische Übersicht in Reviews in Medical Virology, 2024. Written by Alexey Fomenko and 7 co-authors. Institution: Institute of Virology, Medical Center, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany. Major MEDLINE topics: SARS-CoV-2, COVID-19, Sensitivity and Specificity. Cited 4 times so far (Crossref); 79 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: National Research Network of University Medical Centers on COVID-19, Federal Ministry of Education and Research of Germany.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

We aimed to assess the performance of Ag‐RDT and RT‐qPCR with regard to detecting infectious SARS‐CoV‐2 in cell cultures, as their diagnostic test accuracy (DTA) compared to virus isolation remains largely unknown. We searched three databases up to 15 December 2021 for DTA studies. The bivariate model was used to synthesise the estimates. Risk of bias was assessed using QUADAS‐2/C. Twenty studies (2605 respiratory samples) using cell culture and at least one molecular test were identified. All studies were at high or unclear risk of bias in at least one domain. Three comparative DTA studies reported results on Ag‐RDT and RT‐qPCR against cell culture. Two studies evaluated RT‐qPCR against cell culture only. Fifteen studies evaluated Ag‐RDT against cell culture as reference standard in RT‐qPCR‐positive samples. For Ag‐RDT, summary sensitivity was 93% (95% CI 78; 98%) and specificity 87% (95% CI 70; 95%). For RT‐qPCR, summary sensitivity (continuity‐corrected) was 98% (95% CI 95; 99%) and specificity 45% (95% CI 28; 63%). In studies relying on RT‐qPCR‐positive subsamples ( n = 15), the summary sensitivity of Ag‐RDT was 93% (95% CI 92; 93%) and specificity 63% (95% CI 63; 63%). Ag‐RDT show moderately high sensitivity, detecting most but not all samples demonstrated to be infectious based on virus isolation. Although RT‐qPCR exhibits high sensitivity across studies, its low specificity to indicate infectivity raises the question of its general superiority in all clinical settings. Study findings should be interpreted with caution due to the risk of bias, heterogeneity and the imperfect reference standard for infectivity.

Subjects

MeSH terms (MEDLINE)

SARS-CoV-2COVID-19Sensitivity and SpecificityHumansReverse Transcriptase Polymerase Chain ReactionCell Culture TechniquesCOVID-19 TestingCOVID-19 Nucleic Acid TestingRapid Diagnostic Tests

Author keywords

Ag‐RDTRT‐PCRcell culturediagnostic accuracy

Authors and institutions

  • Institute of Virology, Medical Center, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany.
  • Department Clinical Medicine, Institute of General Practice and Health Services Research, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.
  • Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Würzburg, Germany.
  • Institute for Evidence in Medicine, Medical Center - University of Freiburg, Faculty of Medicine, Freiburg, Germany.
  • Cochrane Germany, Cochrane Germany Foundation, Freiburg, Germany.
  • Institute for Biometrics and Epidemiology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University Duesseldorf, Düsseldorf, Germany.

ORCID profiles: Alexey Fomenko, Theo Dähne, Stephanie Weibel, Marcus Panning, Kathrin Grummich, Sabrina Schlesinger, Gerta Rücker, Hartmut Hengel

Funding

  • National Research Network of University Medical Centers on COVID-19
  • Federal Ministry of Education and Research of Germany

Cite

APA

Fomenko, A., Dähne, T., Weibel, S., Panning, M., Grummich, K., Schlesinger, S., Rücker, G., & Hengel, H. (2024). Test accuracy of rapid diagnostic tests and reverse‐transcription polymerase chain reaction against virus isolation in cell culture for assessing SARS‐CoV‐2 infectivity: Systematic review and meta‐analysis. Reviews in Medical Virology. https://doi.org/10.1002/rmv.2569

Vancouver

Fomenko A, Dähne T, Weibel S, Panning M, Grummich K, Schlesinger S, et al. Test accuracy of rapid diagnostic tests and reverse‐transcription polymerase chain reaction against virus isolation in cell culture for assessing SARS‐CoV‐2 infectivity: Systematic review and meta‐analysis. Reviews in Medical Virology. 2024. doi:10.1002/rmv.2569

BibTeX
@article{Fomenko2024,
  author = {Fomenko, Alexey and Dähne, Theo and Weibel, Stephanie and Panning, Marcus and Grummich, Kathrin and Schlesinger, Sabrina and Rücker, Gerta and Hengel, Hartmut},
  title = {Test accuracy of rapid diagnostic tests and reverse‐transcription polymerase chain reaction against virus isolation in cell culture for assessing SARS‐CoV‐2 infectivity: Systematic review and meta‐analysis},
  journal = {Reviews in Medical Virology},
  year = {2024},
  doi = {10.1002/rmv.2569}
}
Start for free →